𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Whole-heart contrast-enhanced coronary magnetic resonance angiography using gradient echo interleaved EPI

✍ Scribed by Himanshu Bhat; Sven Zuehlsdorff; Xiaoming Bi; Debiao Li


Book ID
102953093
Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
671 KB
Volume
61
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Whole‐heart coronary MR angiography (MRA) is a promising method for detecting coronary artery disease. However, the imaging time is relatively long (on the order of 10–15 min). Such a long imaging time may result in patient discomfort and compromise the robustness of whole‐heart coronary MRA due to increased respiratory and cardiac motion artifacts. The goal of this study was to optimize a gradient echo interleaved echo planar imaging (GRE‐EPI) acquisition scheme for reducing the imaging time of contrast‐enhanced whole‐heart coronary MRA. Numerical simulations and phantom studies were used to optimize the GRE‐EPI sequence parameters. Healthy volunteers were scanned with both the proposed GRE‐EPI sequence and a 3D TrueFISP sequence for comparison purposes. Slow infusion (0.5 cc/sec) of Gd‐DTPA was used to enhance the signal‐to‐noise ratio (SNR) of the GRE‐EPI acquisition. Whole‐heart images with the GRE‐EPI technique were acquired with a true resolution of 1.0 × 1.1 × 2.0 mm^3^ in an average scan time of 4.7 ± 0.7 min with an average navigator efficiency of 44 ± 6%. The GRE‐EPI acquisition showed excellent delineation of all the major coronary arteries with scan time reduced by a factor of 2 compared with the TrueFISP acquisition. Magn Reson Med, 2009. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Improved coverage in dynamic contrast-en
✍ Shujun Ding; Steven D. Wolff; Frederick H. Epstein 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 743 KB

An interleaved gradient-echo echo-planar imaging (IGEPI) sequence was modified for and applied to dynamic contrast-enhanced imaging of the heart. Using IGEPI, images with 3.0 x 3.9 mm nominal in-plane resolution are acquired in 100 ms, enabling eight slices per heartbeat for a heart rate of 60 beats

Self-tracking of contrast kinetics for a
✍ Himanshu Bhat; Peng Lai; Debiao Li 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 948 KB

## Abstract ## Purpose To develop a method for automatically triggering centric data acquisition during contrast‐enhanced whole‐heart coronary magnetic resonance angiography (MRA). ## Materials and Methods The hypothesis of this work is that the blood signal changes during contrast infusion can

Volume-targeted and whole-heart coronary
✍ Lijun Tang; Nico Merkle; Michael Schär; Grigorios Korosoglou; Meiyappan Solaiyap 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 220 KB

## Abstract ## Purpose To compare volume‐targeted and whole‐heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. ## Materials and Methods Six healthy adult subjects underwent a navigator‐gated and ‐corrected (NAV) free breathing volume‐

3.0 T contrast-enhanced whole-heart coro
✍ Heng Ma; Qi Yang; Han Li; Xiangying Du; Jing An; Lixin Jin; Lan Ge; Renate Jerec 📂 Article 📅 2010 🏛 BioMed Central 🌐 English ⚖ 266 KB

Reconstructed image examples are shown in Fig. 1a (normal) and b (variation). The angle of the CS ostium was 59°± 7°. The visibility is displayed in Table 2. ## Conclusion 3.0 T contrast-enhanced whole-heart CMRA can clearly depict the cardiac venous anatomy.