## Abstract ## Purpose To optimize the free‐breathing whole‐body diffusion‐weighted imaging (WB‐DWI) protocol by using the short TI inversion‐recovery diffusion‐weighted echo‐planar imaging (STIR‐DWEPI) sequence and the built‐in body coil. Additionally, to evaluate the feasibility of tumor screeni
Whole-body imaging at 7T: Preliminary results
✍ Scribed by J. Thomas Vaughan; Carl J. Snyder; Lance J. DelaBarre; Patrick J. Bolan; Jinfeng Tian; Lizann Bolinger; Gregor Adriany; Peter Andersen; John Strupp; Kamil Ugurbil
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Weight
- 534 KB
- Volume
- 61
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The objective of this study was to investigate the feasibility of whole‐body imaging at 7T. To achieve this objective, new technology and methods were developed. Radio frequency (RF) field distribution and specific absorption rate (SAR) were first explored through numerical modeling. A body coil was then designed and built. Multichannel transmit and receive coils were also developed and implemented. With this new technology in hand, an imaging survey of the “landscape” of the human body at 7T was conducted. Cardiac imaging at 7T appeared to be possible. The potential for breast imaging and spectroscopy was demonstrated. Preliminary results of the first human body imaging at 7T suggest both promise and directions for further development. Magn Reson Med 61:244–248, 2009. © 2008 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract In this study, a method for whole‐body diffusion‐weighted imaging (wbDWI) during continuous table motion has been developed and implemented on a clinical scanner based on a short‐Tau inversion recovery echo‐planar DWI sequence. Unlike currently available multistation wbDWI, which has di
High-resolution (~0.22 mm) images are preferably acquired on whole-body 7T scanners to visualize minianatomic structures in human brain. They usually need long acquisition time (~12 min) in three-dimensional scans, even with both parallel imaging and partial Fourier samplings. The combined use of bo
MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfec
## Abstract Improvements in the echo‐volumar imaging (EVI) technique and its application in whole‐body studies are described. Using an in‐house built 0.5 T echo‐planar imaging system, complete modulus three‐dimensional image data are acquired in 102 ms with real‐time display. Hardware limitations h