## Abstract In this study, a method for whole‐body diffusion‐weighted imaging (wbDWI) during continuous table motion has been developed and implemented on a clinical scanner based on a short‐Tau inversion recovery echo‐planar DWI sequence. Unlike currently available multistation wbDWI, which has di
Whole-body diffusion-weighted imaging: Technical improvement and preliminary results
✍ Scribed by Shuo Li; Fei Sun; Zheng-yu Jin; Hua-dan Xue; Ming-li Li
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 352 KB
- Volume
- 26
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To optimize the free‐breathing whole‐body diffusion‐weighted imaging (WB‐DWI) protocol by using the short TI inversion‐recovery diffusion‐weighted echo‐planar imaging (STIR‐DWEPI) sequence and the built‐in body coil. Additionally, to evaluate the feasibility of tumor screening using high‐resolution three‐dimensional (3D) maximum intensity projection (MIP) images.
Materials and Methods
The prescan procedure of STIR‐DWEPI was modified using the data from 30 volunteers. During each exam, an optimized center frequency (CF) was used to minimize the slice offsets in consecutive scan stations. Prescan time was reduced from 50 seconds to 20 seconds with improved station profile. Total scan time was 30 minutes for five stations and 1.2 m coverage. A total of 30 patients with histologically‐proven malignant disease were scanned under the final protocol using a built‐in body coil. The image quality and the degree of background body signal suppression were assessed.
Results
Free‐breathing WB‐DWI was 100% successfully performed in all patients, without slice misregistration, fat contamination, significant distortion, or nonuniformity. The reconstructed 3D‐MIP images were adequate to depict malignant lesions in all 30 patients. The results of WB‐DWI were found to be comparable to those of single‐photon emission computed tomography (SPECT) and positron emission tomography (PET).
Conclusion
Stable and high‐resolution WB‐DWI is feasible using the technical improvements described in this study. WB‐DWI might have important clinical value for the detection of primary and metastatic malignancies within the whole body. The potential for diagnosis and therapeutic assessment of tumors should be further assessed in a larger patient cohort. J. Magn. Reson. Imaging 2007;26:1139–1144. © 2007 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The objective of this study was to investigate the feasibility of whole‐body imaging at 7T. To achieve this objective, new technology and methods were developed. Radio frequency (RF) field distribution and specific absorption rate (SAR) were first explored through numerical modeling. A
## Abstract ## Purpose: To improve image quality of diffusion‐weighted body magnetic resonance imaging (MRI) with background body signal suppression (DWIBS) at 3.0 T. ## Materials and Methods: In 30 patients and eight volunteers, a diffusion‐weighted spin‐echo echo‐planar imaging sequence with s
## Abstract ## Purpose: To evaluate the usefulness of diffusion‐weighted MR imaging using a transient gustatory stimulation method in patients with xerostomia. ## Materials and Methods: Ten consecutive patients complaining of xerostomia and 10 healthy volunteers were examined with a 1.5 Tesla (T
## Abstract ## Purpose: To evaluate the principal methodological aspects of whole‐body magnetic resonance imaging (MRI) including diffusion‐weighted imaging (DWI) with background suppression using a time‐optimized protocol for restaging of prostate cancer patients in a technical feasibility study.
## Abstract ## Purpose To prospectively compare the capability for bone metastasis assessment of whole‐body diffusion‐weighted imaging (DWI), magnetic resonance imaging (MRI) without and with DWI, [^18^F] fluoro‐2‐D‐glucose positron emission tomography with computed tomography (FDG‐PET/CT) and bon