## Abstract We applied dual‐flex coils in a phased‐array configuration to obtain high resolution MR images of the bilateral hips and compared the image quality with non‐phased‐array imaging. Multiple fast spin‐echo images of both hips were obtained in a single acquisition. Two consecutive acquisiti
Volume imaging with MR phased arrays
✍ Scribed by Cecil E. Hayes; Neil Hattes; Peter B. Roemer
- Publisher
- John Wiley and Sons
- Year
- 1991
- Tongue
- English
- Weight
- 724 KB
- Volume
- 18
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A volume MR phased array was constructed with two coils placed anteriorly and two coils posteriorly. Data acquired simultaneously from the four coils on a phantom were combined into a single image having a signal‐to‐noise ratio 80% better than that from the body coil. Additional comparisons of the four‐coil phased array with a two‐coil phased array and a Helmholtz pair having the same overall dimensions show how variations of signal amplitude and phase in the individual coils affect the composite SNR. Images of the male and female pelvis demonstrate how the improved SNR can be used to reduce the number of excitations, decrease the field of view, increase the echo time, or reduce the slice thickness. © 1991 Academic Press. Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To demonstrate the feasibility of using a double loop phased array endorectal coil combined with a phased array body coil to image the prostate at 3T. ## Materials and Methods We designed and constructed a novel prostate coil employing two arrayed 4.0 × 5.0 cm loops, tuned
## Abstract A method for acquiring pulmonary vascular magnetic resonance (MR) images with either venous or arterial flow suppression is described. The proposed method only marginally increases the overall imaging time compared with conventional flow‐suppression techniques. This enables an acquisiti
An lldR phased-army coil assembly was developed to obtain high-resolution images of atherosclerotic plaques in the carotid artery. Images of volunteere and patients obtained by using alternative coil designs provided a subjective assessment of the coils' performance. field of view, ease of use. and
## Abstract Magnetic resonance (MR) images of the pelvis obtained with an endorectal coil have improved resolution relative to that of body coil images; however, they have limited spatial coverage. The sensitivity profile can be improved by using the endorectal coil combined with an external anteri
## Abstract A flow phantom was used to study MR volume flow measurements for monophasic and triphasic waveforms over the flow range expected in peripheral arteries at rest and with exercise (2–24 mL/sec, __n__ = 50). The improvement in accuracy with phase‐correction image processing to eliminate er