๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Surface coil phased arrays for high-resolution imaging of the carotid arteries

โœ Scribed by Cecil E. Hayes; C. Mark Mathis; Chun Yuan


Publisher
John Wiley and Sons
Year
1996
Tongue
English
Weight
472 KB
Volume
6
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

โœฆ Synopsis


An lldR phased-army coil assembly was developed to obtain high-resolution images of atherosclerotic plaques in the carotid artery. Images of volunteere and patients obtained by using alternative coil designs provided a subjective assessment of the coils' performance. field of view, ease of use. and susceptibility to motion artifacts. A quantitative measurement performed on a phantom indicated that a two-coil phased-array design should produce a 37% better signal-to-noise ratio at the carotids than would a conventional single 3-inch surface coil.


๐Ÿ“œ SIMILAR VOLUMES


Geometrical optimization of a phased arr
โœ A. Liffers; H.H. Quick; C.U. Herborn; H. Ermert; M.E. Ladd ๐Ÿ“‚ Article ๐Ÿ“… 2003 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 363 KB

## Abstract The geometry of an RF phasedโ€array receiving coil for highโ€resolution MRI of the carotid artery, particularly the bifurcation, was optimized with respect to signalโ€toโ€noise ratio (SNR). A simulation tool was developed to determine homogeneity, sensitivity, and SNR for a given imaging si

Transceive surface coil array for magnet
โœ Robert G. Pinkerton; Enzo A. Barberi; Ravi S. Menon ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 339 KB ๐Ÿ‘ 1 views

## Abstract As the static magnetic field strength used in human magnetic resonance imaging increases, the wavelength of the corresponding radiofrequency field becomes comparable to the dimensions of the coil and volume of interest. The dielectric resonance effects that arise in this full wavelength

Improved high resolution MR imaging for
โœ Elizabeth A. Vokurka; Nick A. Watson; Yvon Watson; Neil A. Thacker; Alan Jackson ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 283 KB

## Abstract This study examined the effects of a recently developed automated intensity nonโ€uniformity correction on surface coil images using the orbit as an exemplar. Images were obtained using a standard head coil and a range of surface coils. Slices through the optic nerve head and cavernous si

Parallel imaging technique for the exter
โœ Tadateru Sumi; Misa Sumi; Marc Van Cauteren; Yasuo Kimura; Takashi Nakamura ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 491 KB

## Abstract ## Purpose To evaluate the parallel imaging technique in the external carotid artery and its branches using 3D balanced turbo field echo (3D bTFE), 3D phaseโ€contrast (3D PC), and 3D timeโ€ofโ€flight (3D TOF) MR angiography (MRA) sequences. ## Materials and Methods A total of 26 healthy