Validity and power in hemodynamic response modeling: A comparison study and a new approach
✍ Scribed by Martin A. Lindquist; Tor D. Wager
- Book ID
- 102847282
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 641 KB
- Volume
- 28
- Category
- Article
- ISSN
- 1065-9471
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
One of the advantages of event‐related functional MRI (fMRI) is that it permits estimation of the shape of the hemodynamic response function (HRF) elicited by cognitive events. Although studies to date have focused almost exclusively on the magnitude of evoked HRFs across different tasks, there is growing interest in testing other statistics, such as the time‐to‐peak and duration of activation as well. Although there are many ways to estimate such parameters, we suggest three criteria for optimal estimation: 1) the relationship between parameter estimates and neural activity must be as transparent as possible; 2) parameter estimates should be independent of one another, so that true differences among conditions in one parameter (e.g., hemodynamic response delay) are not confused for apparent differences in other parameters (e.g., magnitude); and 3) statistical power should be maximized. In this work, we introduce a new modeling technique, based on the superposition of three inverse logit functions (IL), designed to achieve these criteria. In simulations based on real fMRI data, we compare the IL model with several other popular methods, including smooth finite impulse response (FIR) models, the canonical HRF with derivatives, nonlinear fits using a canonical HRF, and a standard canonical model. The IL model achieves the best overall balance between parameter interpretability and power. The FIR model was the next‐best choice, with gains in power at some cost to parameter independence. We provide software implementing the IL model. Hum Brain Mapp 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
A quantitati¨e ¨alidation procedure for comparisons of modeled and experimental data is described. This produces se¨eral le¨els of information, from a straightforward numerical assessment to detailed diagnostic data. Results show that this method has significant ad¨antages o¨er a ¨isual approach in
Baroreflex (BR) testing with phenylephrine (PE) and amyl nitrite (AN) provided an opportunity to evaluate the ability of impedance cardiography (IC) to track the rapid hemodynamic (HD) changes elicited by these drugs. The AN response was measured after inhalation and the PE response was measured aft