𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Validation of flow cytometric competitive binding protocols and characterization of fluorescently labeled ligands

✍ Scribed by Anna Waller; David Pipkorn; Karyn L. Sutton; Jennifer J. Linderman; Geneva M. Omann


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
435 KB
Volume
45
Category
Article
ISSN
0196-4763

No coin nor oath required. For personal study only.

✦ Synopsis


Background: Fluorescently labeled ligands and flow cytometric methods allow quantification of receptor-ligand binding. Such methods require calibration of the fluorescence of bound ligands. Moreover, binding of unlabeled ligands can be calculated based on their abilities to compete with a labeled ligand. In this study, calibration parameters were determined for six fluorescently labeled N-formyl peptides that bind to receptors on neutrophils. Two of these ligands were then used to develop and validate competitive binding protocols for determining binding constants of unlabeled ligands. Methods: Spectrofluorometric and flow cytometric methods for converting relative flow cytometric intensities to number of bound ligand/cell were extended to include peptides labeled with fluorescein, Bodipy, and tetramethylrhodamine. The validity of flow cytometric competitive binding protocols was tested using two ligands with different fluorescent properties that allowed determination of rate constants both directly and competitively for one ligand, CHO-NLFNYK-tetramethylrhodamine. Results: Calibration parameters were determined for six fluorescently-labeled N-formyl peptides. Equilibrium dissociation constants for these ligands varied over two orders of magnitude and depended upon the peptide sequence and the molecular structure of the fluorescent tag. Kinetic rate constants for CHO-NLFNYK-tetramethylrhodamine determined directly or in competition with CHO-NLFNYK-fluorescein were statistically identical. Conclusions: Combination of spectrofluorometric and flow cytometric methods allows convenient calculation of calibration parameters for a series of fluorescent ligands that bind to the same receptor site. Competitive binding protocols have been independently validated. Cytometry 45: 102-114, 2001.


πŸ“œ SIMILAR VOLUMES


Flow cytometric competitive binding assa
✍ George C. Saunders; John C. Martin; James H. Jett; Ann Perkins πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 239 KB

## Abstract A single step, separation free competitive binding reaction between the fluorescent antibiotic mithramycin and actinomycin‐D for common binding sites on DNA coated 10 ΞΌm diameter microspheres is described. The fluorescence of the microspheres is measured with a flowcytometer. In the pre

Flow cytometric characterization and cla
✍ Jan F. Keij; John A. Steinkamp πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 93 KB πŸ‘ 1 views

FlowMetrix (Luminex, Austin, TX) microspheres were recently introduced as a platform for beadbased assays involving antibodies, enzymes, toxins, and nucleic acids. The procedure involves classification of the microspheres by their orange and red fluorescence and quantitation of the BODIPY-tagged bio

Flow cytometric measurement of kinetic a
✍ Bohumil Bednar; Michael E. Cunningham; Patricia A. McQueney; Melissa S. Egbertso πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 142 KB πŸ‘ 2 views

Antagonists of platelet glycoprotein IIb/IIIa (GPIIb/IIIa) represent a new therapeutic approach in inhibiting platelet aggregation, thus providing a powerful form of antithrombotic therapy. The measurement of binding of arginine-glycine-aspartic acid (RGD) peptidomimetics to GPIIb/IIIa on platelets

Label-free determination of protein–liga
✍ Matthias C. Jecklin; Stefan Schauer; Christoph E. Dumelin; Renato Zenobi πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 432 KB

## Abstract We performed a systematic comparison of three label‐free methods for quantitative assessment of binding strengths of proteins interacting with small molecule ligands. The performance of (1) nanoelectrospray ionization mass spectrometry (nESI‐MS), (2) surface plasmon resonance (SPR), and

Flow-through partial-filling affinity ca
✍ John Kaddis; Erica Mito; Joseph Heintz; Alfredo Plazas; Frank A. Gomez πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 109 KB

This work evaluates the use of a competitive binding assay using flow-through partial-filling affinity capillary electrophoresis (FTPFACE) to estimate binding constants of neutral ligands to a receptor. We demonstrate this technique using, as a model system, carbonic anhydrase B (CAB, EC 4.2.1.1) an