## Abstract A new method for the determination of the orientation of organic molecules with partially known stereochemistry in the unit cell is described and compared with the convolution molecule method by Hoppe and Paulus.
Validation of a new method for determination of cup orientation in THA
✍ Scribed by Simon D. Steppacher; Moritz Tannast; Guoyan Zheng; Xuan Zhang; Jens Kowal; Suzanne E. Anderson; Klaus A. Siebenrock; Stephen B. Murphy
- Publisher
- Elsevier Science
- Year
- 2009
- Tongue
- English
- Weight
- 182 KB
- Volume
- 27
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D‐model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 ± 1.7° (−3.7° to 4.0°) for inclination and 1.2 ± 2.4° (−5.3° to 5.6°) for anteversion in the cadaver trials and 1.7 ± 1.7° (−4.6° to 5.5°) for inclination and 0.9 ± 2.8° (−5.2° to 5.7°) for anteversion in the clinical data when compared to CT‐based measurements. No systematic errors in accuracy were detected with the Bland–Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D‐matching technique. Its robust and accurate matching algorithm can be expanded to statistical models. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:1583–1588, 2009
📜 SIMILAR VOLUMES
## Abstract An analytical method based on CZE to determine lansoprazole enantiomers in pharmaceuticals was developed. The primary factors affecting its separation efficiency, which include chiral selector, pH, buffer concentration, capillary temperature and injection time, were optimised. The best
## Abstract Trihalomethanes (THMs), chlorinated by‐products in drinking water, have been determined by comparing some analytical methods, based on the following techniques: liquid–liquid extraction‐gas chromatography‐mass spectrometry (LLE‐GC‐MS), headspace‐gas chromatography‐mass spectrometry (hea
A new, particularlv simple and reliable method OJ yuantitativejuorine analysis is described; it is based on ihe conversion of insoluble silver oxide into soluble silver fluoride by jluorosilicic acid released from the sample by Willard-Winter-Tananaev steam distillation, the silver fluoride then bei