𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Validation and quantification of an in vitro model of continuous infusion of submicron-sized particles

✍ Scribed by Steven G. Ortiz; Ting Ma; Noah J. Epstein; R. Lane Smith; Stuart B. Goodman


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
150 KB
Volume
84B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Wear particles produced from total joint replacements have been shown to stimulate a foreign body and chronic inflammatory reaction that results in periprosthetic osteolysis. Most animal models that simulate these events have used a single injection of particles, which is not representative of the clinical scenario, in which particles are continuously generated. The goal of this study was to evaluate the feasibility of an osmotic pump for the continuous delivery of clinically relevant submicron‐sized particles over an extended period of time. Blue‐dyed polystyrene particles and retrieved ultra‐high molecular weight polyethylene (UHMWPE) particles, both suspended in mouse serum, were loaded into an Alzet mini‐osmotic pump. Pumps were attached to vinyl tubing that ended with hollow titanium rods, simulating a metal implant, which was suspended in a collection vessel. The number of particles collected was evaluated over 2‐ and 4‐week time periods. Delivery of both the polystyrene and UHMWPE particles was feasible over pump concentrations of 10^9^ to 10^11^ particles per pump. Furthermore, delivery efficiency of polystyrene particles decreased with increasing initial particle concentration, whereas delivery efficiency of UHMWPE particles increased slightly with increasing initial particle concentration. For UHMWPE, approximately one‐third of the particles in the pump were collected at 4 weeks. This in vitro study has quantified the efficiency of a unique particle pumping system that may be used in future in vivo investigations to develop a murine model of continuous particle infusion. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 2008


📜 SIMILAR VOLUMES


In vivo murine model of continuous intra
✍ Ting Ma; Steven G. Ortiz; Zhinong Huang; Peigen Ren; R. Lane Smith; Stuart B. Go 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 181 KB

## Abstract Continued production of wear debris affects both initial osseointegration and subsequent bone remodeling of total joint replacements (TJRs). However, continuous delivery of clinically relevant particles using a viable, cost effective, quantitative animal model to simulate the scenario i

Quantification of multicontrast vascular
✍ Catherine Desbleds Mansard; Emmanuelle P. Canet Soulas; Alfred Anwander; Linda C 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 343 KB

## Abstract Vessel‐wall measurements from multicontrast MRI provide information on plaque structure and evolution. This requires the extraction of numerous contours. In this work a contour‐extraction method is proposed that uses an active contour model (NLSnake) adapted for a wide range of MR vascu

Prediction of precipitation-induced phle
✍ Jennifer L. H. Johnson; Yan He; Samuel H. Yalkowsky 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 111 KB

To avoid phlebitis, new intravenous (IV) parenterals are often screened by injection into animals. This method is not only expensive and time consuming, it is also detrimental to the animals. An alternate method, focusing on precipitation as the cause, uses an in vitro dynamic injection model that r

Validation of an in vitro model for asse
✍ Saura C. Sahu; Paddy L. Wiesenfeld; Chung S. Kim; Ivan A. Ross; Philip P. Sapien 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 95 KB 👁 1 views

## Abstract Androstenedione, a naturally occurring steroid hormone, has been used to enhance athletic performance. Little is known, however, about its hepatotoxicity. Clone‐9 cells, a non‐transformed epithelial cell line that was originally isolated from normal liver of a 4‐week old Sprague‐Dawley