Validated method for determination of bromopride in human plasma by liquid chromatography–electrospray tandem mass spectrometry: application to the bioequivalence study
✍ Scribed by P. Nazare; P. Massaroti; L. F. Duarte; D. R. Campos; M. A. M. Marchioretto; G. Bernasconi; S. Calafatti; F. A. P. Barros; E. C. Meurer; J. Pedrazzoli; L. A. B. Moraes
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 143 KB
- Volume
- 40
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.898
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A simple, sensitive and specific liquid chromatography‐tandem mass spectrometry method for the quantification of bromopride I in human plasma is presented. Sample preparation consisted of the addition of procainamide II as the internal standard, liquid‐liquid extraction in alkaline conditions using hexane‐ethyl acetate (1 : 1, v/v) as the extracting solvent, followed by centrifugation, evaporation of the solvent and sample reconstitution in acetonitrile. Both I and II (internal standard, IS) were analyzed using a C18 column and the mobile‐phase acetonitrile‐water (formic acid 0.1%). The eluted compounds were monitored using electrospray tandem mass spectrometry. The analyses were carried out by multiple reaction monitoring (MRM) using the parent‐to‐daughter combinations of m/z 344.20 > 271.00 and m/z 236.30 > 163.10. The areas of peaks from analyte and IS were used for quantification of I. The achieved limit of quantification was 1.0 ng/ml and the assay exhibited a linear dynamic range of 1–100.0 ng/ml and gave a correlation coefficient (r) of 0.995 or better. Validation results on linearity, specificity, accuracy, precision and stability, as well as application to the analysis of samples taken up to 24 h after oral administration of 10 mg of I in healthy volunteers demonstrated the applicability to bioequivalence studies. Copyright © 2005 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
## Abstract A rapid, sensitive and specific analytical method was developed and validated to quantify gabapentin in human plasma using acetaminophen as an internal standard. The method employs a single plasma protein precipitation. The analytes are chromatographed on a C~4~ reversed‐phase chromatog
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 mi
## Abstract A rapid, sensitive and specific method to quantify ticlopidine in human plasma using clopidogrel as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid–liquid extraction using diethyl ether–hexane (80 : 20, v/v). The extracts we
## Abstract A rapid, sensitive and specific high‐performance liquid chromatography‐electrospray ionization mass spectrometry (LC/ESI‐MS) method was developed and validated for the first time to determine the concentration of lafutidine in human plasma. After the addition of diazepam (the internal s
## Abstract A method based on liquid chromatography with negative ion electrospray ionization and tandem mass spectrometry is described for the determination of nimesulide in human plasma. Liquid–liquid extraction using a mixture of diethyl ether and dichloromethane was employed and celecoxib was u