## Abstract A rapid, sensitive and specific analytical method was developed and validated to quantify gabapentin in human plasma using acetaminophen as an internal standard. The method employs a single plasma protein precipitation. The analytes are chromatographed on a C~4~ reversed‐phase chromatog
Nevirapine quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
✍ Scribed by Tiago L. Laurito; Vincenzo Santagada; Giuseppe Caliendo; Celso H. Oliveira; Rafael E. Barrientos-Astigarraga; Gilberto De Nucci
- Publisher
- John Wiley and Sons
- Year
- 2002
- Tongue
- English
- Weight
- 156 KB
- Volume
- 37
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.300
No coin nor oath required. For personal study only.
✦ Synopsis
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.
📜 SIMILAR VOLUMES
## Abstract A rapid, sensitive and specific method to quantify ticlopidine in human plasma using clopidogrel as the internal standard (IS) is described. The analyte and the IS were extracted from acidified plasma by liquid–liquid extraction using diethyl ether–hexane (80 : 20, v/v). The extracts we
## Abstract A method based on liquid chromatography with negative ion electrospray ionization and tandem mass spectrometry is described for the determination of nimesulide in human plasma. Liquid–liquid extraction using a mixture of diethyl ether and dichloromethane was employed and celecoxib was u
## Abstract A rapid, sensitive and specific method for quantifying clonazepam in human plasma using diazepam as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid‐liquid extraction using a hexane/diethylether (20 : 80, v/v) solution. The extracts we