โœฆ Synopsis


Microvascular anastomosis is a demanding skill requiring technical excellence and a thorough knowledge of anatomy and physiology. Every suture placed in a microvascular anastomosis should be considered critical as each has the potential to compromise the delicate reconstruction. As such, any device that can facilitate microvascular suture placement deserves thorough evaluation. The U-clip (Coalescent Surgical, Sunnyvale, CA) is such a device in that it eliminates the often time consuming process of tying knots. We evaluated use of the U-clip in microvascular anastomosis of a 1.5 mm artery. We found the U-clip to offer some advantages including ease of use, traditional feel of directed suture placement (as compared to couplers), and elimination of time needed for knot tying. Its shortcomings include size (in diameter, the "pop-off" section of the device appears larger than standard 8-0 suture), the significant force required to "pop-off" the device and difficulty removing the device.


๐Ÿ“œ SIMILAR VOLUMES


Use of a tilted double clamp in microvas
โœ P. M. Hendel; Dr. Harry J. Buncke ๐Ÿ“‚ Article ๐Ÿ“… 1980 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 248 KB

## Abstract A tilted or angulated double microvascular clamp is described that, when applied to the vessels to be anastomosed, presents the vessel ends angulated upward facing the surgeon, so that the initial suturing of the posterior wall can be completed without rotating the vessel. Such a clamp

The ring technique for end-to-side micro
โœ Harry P. Weinrib; John Querin Cook; Richard D. Penn ๐Ÿ“‚ Article ๐Ÿ“… 1984 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 288 KB

The ring technique for end-to-side microvascular anastomosis employs a resorbable polyglycolic acid ring to prevent stenosis and spasm at the anastomotic site. In 20 rats, the ring technique was compared with the conventional technique for constructing end-to-side anastomoses between the femoral (0.

The effect of stasis on a microvascular
โœ Enrique J. Fernandez; Richard D. Nadal; Sandy M. Gonzalez; H. Hollis Caffee ๐Ÿ“‚ Article ๐Ÿ“… 1983 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 221 KB
Use of Teflon stents for lymphovenous an
โœ N. J. Shaper; D. R. Rutt; Professor N. L. Browse ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 471 KB

## Use of Teflon stents for lymphovenous anastomosis The treatment of Iymphoedema is dificult; conservative and surgical management show variable results. Lymphovenous anastomoses ( L VAs) in experimental animals and patients give poor results in the treatment of primary lymphoedema and variable r