Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is shown to give inaccurate results for the analysis of low molecular weight ethoxylate polymers. It is demonstrated that when the degree of ethoxylation is low (n < 9), MALDI-TOFMS produces substantially high
Use of meso- tetrakis(pentafluorophenyl)porphyrin as a matrix for low molecular weight alkylphenol ethoxylates in laser desorption/ ionization time-of-flight mass spectrometry
โ Scribed by F. O. Ayorinde; P. Hambright; T. N. Porter; Q. L. Keith Jr.
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 98 KB
- Volume
- 13
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
The use of UV-absorbing molecules as matrices in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) is well documented. The matrices that are currently used have low molecular weights (`300 Da) and thus, for a typical MALDI-TOF spectrum, the low-mass range (m/z 100-500) is dominated by matrix ions. Consequently, the applications of MALDI-TOFMS have been restricted mostly to the analysis of high molecular weight analytes. This report demonstrates the use of mesotetrakis(pentafluorophenyl)porphyrin (F20TPP, MW 974.57) as a matrix in the MALDI-TOF mass spectrometric analysis of some commercial nonylphenol ethoxylates (4-(C 9 H 19 )-C 6 H 4 -(OCH 2 CH 2 ) n -OH), in which the ethoxymer ion distribution ranges from 331-771 Da. When F20TPP was used without a sodium ion dopant, there were no MALDI signals for the ethoxylates. However, addition of sodium acetate to the sample produced MALDI spectra in which the ethoxymer molecules were sodiated to form [M Na] ions. A comparison of the mass spectrometric data with those obtained when a-cyano-4-hydroxycinnamic acid (CHCA) was used as the matrix indicated that the F20TPP-induced spectra provided comparable data, with the advantage of having less matrix interference in the low-mass range (m/z 100-500). Thus, the use of F20TPP and similar porphyrins may provide the means to apply MALDI-TOF to the analysis of low molecular weight molecules with minimum interference from matrix signals.
๐ SIMILAR VOLUMES
Use of the matrix-assisted laser desorption/ionization matrix 2-hydroxy-1-naphthoic acid provides a 2-4foM enhancement of ion signal for low molecular mass porphyrins over other matrices including a-cyano-4hydroxycinnamic acid, 2-(4-hydroxyphenylazo)benzoic acid, sinapinic acid and 2,Sdibydroxybenzo
Recent interest in the environmental fate and impact of nonylphenol ethoxylates (NPEs) has necessitated the need for the development of specific, and yet efficient, analytical methodologies for their detection. Using seventeen commercial NPEs, all having the general formula 4-(C(9)H(19))-C(6)H(4)-(O
We report that commercially available b-carbolines (nor-harmane (9H-pyrido[3,4-b]indole), harmane (1methyl-9H-pyrido[3,4-b]indole), harmine (7-methoxy-1-methyl-9H-pyrido[3,4-b]indole), harmol (1-methyl-9H-pyrido[3,4-b]indol-7-ol), harmaline (3,4-dihydro-7-methoxy-1-methyl-9H-pyrido[3,4-b]indole) and