𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Urologic dosimetry studies with the Nd: YAG and CO2 lasers: Bladder and kidney

✍ Scribed by Barry S. Stein


Publisher
John Wiley and Sons
Year
1986
Tongue
English
Weight
930 KB
Volume
6
Category
Article
ISSN
0196-8092

No coin nor oath required. For personal study only.

✦ Synopsis


Dose recommendations for the use of the Nd:YAG and CO2 lasers have been accepted with little laboratory analysis. We have examined both endoscopic and open applications in the bladder and open applications on the kidney with the lasers over a variety of power and pulse duration settings. In addition, we have studied the effect of varying the temperature of the tissue and irrigation solution on the depth of penetration. We found that with the Nd:YAG laser, the maximum depth of penetration in our animal model was only 2.62 mm in the bladder. This occurred during an endoscopic treatment with settings of 50 W at 4 seconds with irrigation solution of 25 degrees C. The depth of penetration using current recommendations of 40 W for 2 seconds was less than 1 mm at all temperatures. Room temperature irrigation solution may be the ideal compromise, but higher-power long-pulse durations or repeated treatments to the same area may be necessary to achieve penetrations of 3-5 mm. In open applications on bladder and kidney, the maximum depth of penetration in our animal model was 2.75 mm, which was found during a treatment with settings of 60 W at 4 seconds with the kidney parenchyma at 25 degrees C. Using the CO2 laser on open applications of bladder strips, we obtained a maximum depth of penetration of 1.75 mm at 30 W of power for 1/2 second at 85 degrees C tissue temperature. Unfortunately, penetration by the CO2 laser is accompanied by vaporization of tissue, leaving a large crater. Minimal injury exists beyond this area. In the kidney, we obtained a maximum depth of penetration of 1.75 mm at 30 W of power at 25 degrees C and 20 W of power at 2 degrees C each for 1/2 second.


πŸ“œ SIMILAR VOLUMES


Partial nephrectomy with a combined CO2
✍ Dr. Kimmo Taari; Jaakko O. Salo; Sakari Rannikko; Stig Nordling πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 365 KB πŸ‘ 1 views

## Abstract Twenty‐eight partial nephrectomies were performed on nine pigs with a simultaneous, coaxial CO~2~‐Nd:YAG laser at power settings of 20 W and 40 W, or with a steel scalpel. A vascular pedicle clamp was used without renal cooling. The time for hemostasis was 4.5 Β± 3.2 min (mean Β± SD) with

Experimental study of partial liver rese
✍ Priv. Doz. Dr. med. H.-J. Meyer; K. Haverkampf πŸ“‚ Article πŸ“… 1982 πŸ› John Wiley and Sons 🌐 English βš– 422 KB πŸ‘ 1 views

## Abstract The use of the CO~2~ laser in liver surgery is mainly limited by the lack of coagulation of the larger vessels. In an experimental study, partial liver resections were performed on pigs with a Nd:YAG as well as with a combined CO~2~ and Nd: YAG laser. The best cutting efficiency was obt

Observations on the simultaneous use of
✍ Victor Aldo Fasano; Franco Benech; Roberto Maria Ponzio πŸ“‚ Article πŸ“… 1982 πŸ› John Wiley and Sons 🌐 English βš– 499 KB πŸ‘ 1 views

## Abstract Seven cases of cerebral tumors (four deep‐seated sovratentorial gliomas located in motor area, occipital region, parietal region and frontal region; one deep‐seated cystic cerebellar spongioblastoma; one sphenoidal wing meningioma, and one spinal cord intradural tumor) were simultaneous

Comparison of local tumor recurrence fol
✍ Raymond J. Lanzafame; Kang Qiu; David W. Rogers; John O. Naim; Fred C. Caldwell; πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 515 KB

This study compares the incidence of local tumor recurrence following primary excision with the CO2 laser, Nd:YAG laser (contact), Argon Beam Coagulator, or electrocautery. One hundred eight Fisher 344 rats with R3230AC mammary tumors (1.6 k 0.04 [SD] cm diameter) were used. All animals were randomi