𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Unified gas and supercritical fluid chromatography on 50 μm i.d. Columns

✍ Scribed by Tong, Daixin ;Bartle, Keith D. ;Clifford, Anthony A. ;Robinson, Robert E.


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
406 KB
Volume
15
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A unified approach to sequential gas and supercritical fluid Chromatography using 50 μm i.d. open tubular columns is described. Sample introduction is performed by means of a rotary injection valve. In order that linear velocities can be optimized independently, a second rotary valve in the chromatographic oven is used to direct the flow of column eluate to the flame ionization detector through either fused silica tubing in GC, or a frit restrictor in SFC.

Applications of sequential GC‐SFC on a 50 μm i.d. open tubular column are demonstrated, and comparisons made between sequential GC‐SFC on 50 and 100 μm i.d. columns.


📜 SIMILAR VOLUMES


Unified open tubular column chromatograp
✍ Robert E. Robinson; Daixin Tong; Robert Moulder; Keith D. Bartle; Anthony A. Cli 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 545 KB

## Abstract A unified chromatograph was constructed in which open tubular column gas chromatography, at normal helium carrier gas pressures, followed by supercritical fluid chromatography with carbon dioxide mobile phase was carried out in a single run using a 100‐μm i. d. column. Sample introducti

On-line multidimensional supercritical f
✍ Levy, J. M. ;Guzowski, J. P. ;Huhak, W. E. 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 323 KB 👁 1 views

A new analytical technique combining on-line supercritical fluid chromatography with capillary gas chromatography has been developed. The supercritical fluid sample effluent is decompressed througha restrictordirectlyintoaconventionalcapillary gas chromatographic injection port. This technique allow

Narrow (5-50-μm i.d.) open tubular colum
✍ Karin Göhlin; Marita Larsson 📂 Article 📅 1991 🏛 John Wiley and Sons 🌐 English ⚖ 741 KB

## Abstract This paper presents in detail the preparation of highly efficient, stable open tubular (OT) columns for reversed‐phase liquid chromatography. Chromatographic properties of 5‐50‐μm i.d. fused silica columns (1.5‐5 m in length) are described, and details of the coating procedure are discu

Preparation, evaluation, and comparison
✍ Aerts, A. ;Rijks, J. ;Bemgard, A. ;Blomberg, L. 📂 Article 📅 1986 🏛 John Wiley and Sons 🌐 English ⚖ 627 KB

The preparation of wide bore (320 pm) and narrow bore (50 pm) fused silica capillary columns is described for immobilized cyanopropyl substituted silicones containing 60 and 88% substitution. The effect of high temperature deactivation with cyanopropylcyclosiloxanes was studied with a special test m