๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Umbilical venous pulsatility and volume blood flow in complicated pregnancies: Correlation with the umbilical artery blood velocity waveforms

โœ Scribed by Krzysztof Preis; Saemundur Gudmundsson; Karel Marsal


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
411 KB
Volume
2
Category
Article
ISSN
0929-8266

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Umbilical artery blood flow velocity in
โœ Farine, Dan; Granovsky-Grisaru, Sorina; Ryan, Greg; Seaward, P. Gareth R.; Teoh, ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 62 KB

Purpose. We evaluated the role of umbilical artery Doppler velocimetry in the surveillance of pregnancies complicated by systemic lupus erythematosus (SLE). Methods. We retrospectively studied 56 women with SLE whose pregnancies were managed at our perinatal center between 1988 and 1995. Results.

Renal blood flow velocity in neonates wi
โœ Julie S. Glickstein; Monika Rutkowski; Robert Schacht; Deborah Friedman ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 772 KB

We performed an observational prospective cohort study on the applicability of two-dimensional echocardiography with pulsed Doppler technique as a noninvasive modality to serially evaluate renal blood velocities in premature neonates with and without umbilical artery catheters. We also sought to det

Doppler blood velocity waveforms in the
โœ Dr. Deborah M. Friedman; Monika Rutkowski; Jon R. Snyder; Ilana Lustig-Gillman; ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 889 KB

Doppler blood velocity waveforms were analyzed from the umbilical artery as an indication of fetal well-being. Since the ratio of systolic to diastolic peak flows (A/ B) reflects placental vascular resistance, an abnormality of this value may accurately predict compromised fetuses. Twenty-one studie

Umbilical artery Doppler flow-velocity w
โœ Jesper Legarth; Goran Lingman; Magnus Stangenberg; Feryal Rahman ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 428 KB

Pulsed-Doppler examinations of blood-flow velocities in the umbilical ar- tery were carried out before and after 15 diagnostic cordocenteses and 34 fetal blood transfusions into the umbilical vein. There were decreases in the systolic/diastolic ratio (A/B) ( p < 0.01), the pulsatility index (PI) (p

Comparison of blood velocity waveform in
โœ J. M. G Van Vugt; C. J Ruissen; S. J Nienhuis; H. J Hoogland; J de Haan ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 332 KB

A comparison was made between the AB ratio, resistance index (RI), and pulsatility index (PI 1, calculated from tracings obtained by pulsed Doppler (PD) and continuous wave ( C W ) Doppler devices in 14 uncomplicated singleton pregnancies. The AB ratio, RI, and PI were a slightly higher for the CW D

Umbilical artery catheters and blood flo
โœ Shah, Jayesh B.; Bracero, Luis A.; Gewitz, Michael H.; Fish, Bernard G.; Dweck, ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 36 KB ๐Ÿ‘ 2 views

Purpose. We studied whether umbilical artery catheters (UACs) affect blood flow in the superior mesenteric artery (SMA) of neonates. Methods. Noninvasive duplex pulsed Doppler sonography was used to measure peak systolic velocity, end-diastolic velocity, and mean flow velocity in the SMA. The resis