A numerical approach for the synthesis of multivariable controllers from plant input-output data is presented. The method is applicable whenever a system is open-loop stable, redundantly actuated, and when its transfer function matrix is of full rank for all s. The method has two major advantages. F
Tuning of fuzzy controller for an open-loop unstable system: a genetic approach
β Scribed by P.T. Chan; W.F. Xie; A.B. Rad
- Publisher
- Elsevier Science
- Year
- 2000
- Tongue
- English
- Weight
- 544 KB
- Volume
- 111
- Category
- Article
- ISSN
- 0165-0114
No coin nor oath required. For personal study only.
β¦ Synopsis
The design, test and evaluation of an optimised fuzzy logic controller (OFLC) is reported in this paper. With the aid of genetic algorithms (GA), the rule-base of an otherwise standard fuzzy logic controller (FLC) is obtained. This is achieved by deriving a tailor-made encoding scheme, initialisation, crossover and mutation of rule table into strings of integers. GA is implemented such that the existing knowledge of the system is utilised to increase the speed of optimisation. The OFLC is successfully applied to control an open-loop unstable system -the ball-and-beam balance system -on a hardware test-bed. A Kalman ΓΏlter controller (KFC) and a manually tuned fuzzy logic controller (MFLC) are also developed for the test-bed and the performances of the three controllers are compared. The experiment reveals that improved robustness with shorter design cycle can be achieved by integrating GA into an FLC.
π SIMILAR VOLUMES
Nonlinear dynamic matrix control of an open-loop unstable process with least-squares minimization for constraints'
This paper describes a new parameter tuning method for an elevator group control system. In such a system, tuning parameters describing elevator use and the building environment are important. The new tuning method uses improved genetic algorithms to follow environment changes and to give robustness
The real time implementation of closed loop control laws obtained by the minimization of a quadratic criterion with finite time intervals is a difficult problem, if we consider computing time and the eventual determination of the state variables. It would seem useful therefore to define, for complex
The synthesis of the control system of an overall boiler-turbine process represents a non-trivial design problem. Significant improvements may be achieved, both in terms of efficiency and plant availability, if control functions are well organized. Complex control system architectures may be conceiv