Trace elements analysis in biological samples by radioisotopic X-ray fluorescence

✍ Scribed by R. Cesareo


Publisher
Springer
Year
1976
Tongue
English
Weight
453 KB
Volume
1
Category
Article
ISSN
0340-6997

No coin nor oath required. For personal study only.

✦ Synopsis


The X-ray fluorescence technique, induced by radioisotopic sources, provides a very simple method for the simultaneous analysis of trace elements in biological samples. For blood, serum, platelets, etc., samples of about 0.1 ml were deposited on filter paper disks, dried, and analyzed. In such a way the "thin specimen" approximation is realized, resulting in the following advantages: The X-ray intensity of a given element is a liner function of mass per unit area over several orders of magnitude. Interelement effects became negligible. The ratio of fluorescent X-rays to scattered radiation is increased. The sensitivity of the technique for elements with atomic number ranging from about 20-92 varies from some units to some tens of parts per million by weight in 100 s measuring time, by using a gas proportional counter, and from about some tenths to some parts per million by using an X-ray semiconductor detector, in a measuring time of 10(3)-10(4)s. In such a way and with the described features, the Cl, K, Ca, Fe, Cu, Zn, Br content of several speciments of blood and serum was determined. Measurements were further carried out in order to labelling blood components with stable tracers and to detect their concentration by means of the X-ray fluorescence technique. The life span of platelets was, for example, measured after labelling platelets with stable Selenocystine. The sensitivity of the XRF technique can further be enhanced by about three orders of magnitude by using a pre-enrichment step with ion-exchange resins and liquid volumes not lower than 500 ml. Urine analyses have been carried in such a way, and copper in about 20 ml serum after selective extraction.


πŸ“œ SIMILAR VOLUMES


Analysis of major, minor and trace eleme
✍ G.P Suarez-Fernandez; J.M.G Vega; A.B Fuertes; A.B Garcia; M.R Martı́nez-Tarazon πŸ“‚ Article πŸ“… 2001 πŸ› Elsevier Science 🌐 English βš– 96 KB

The evaluation of the energy dispersive X-ray Β―uorescence spectroscopy method, for the analysis of major, minor and trace elements present in the mineral matter of coal, using an apparatus with sources of radioisotope elements, is described. Analyses were performed on both coal and coal ash samples