Italy is organizing a course on 2-4 May 2007, with the patronage of the Italian Cell Culture Association. This course intends to provide training to students and senior scientists working on biomedical problems about state of the art methods (focusing on time-lapse techniques) for live cell imaging
Time-resolved microscopy for imaging lanthanide luminescence in living cells
✍ Scribed by Nivriti Gahlaut; Lawrence W. Miller
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 516 KB
- Volume
- 77A
- Category
- Article
- ISSN
- 0196-4763
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Time‐resolved luminescence (TRL) microscopy can image signals from lanthanide coordination complexes or other probes with long emission lifetimes, thereby eliminating short‐lifetime (<100 ns) autofluorescence background from biological specimens. However, lanthanide complexes emit far fewer photons per unit time than conventional fluorescent probes, making it difficult to rapidly acquire high quality images at probe concentrations that are relevant to live cell experiments. This article describes the development and characterization of a TRL microscope that employs a light‐emitting diode (LED, λ~em~ = 365 nm) for pulsed epi‐illumination and an intensified charge‐coupled device (ICCD) camera for gated, widefield detection. Europium chelate‐impregnated microspheres were used to evaluate instrument performance in terms of short‐lifetime fluorescence background rejection, photon collection efficiency, image contrast, and signal‐to‐noise ratio (SNR). About 200 nm microspheres were imaged within the time resolution limit of the ICCD (66.7 ms) with complete autofluorescence suppression. About 40 nm microspheres containing ∼400 chelate molecules were detected within ∼1‐s acquisition times. A luminescent terbium complex, Lumi4‐Tb®, was introduced into the cytoplasm of cultured cells at an estimated concentration of 300 nM by the method of osmotic lysis of pinocytic vesicles. Time‐resolved images of the living, terbium complex‐loaded cells were acquired within acquisition times as short as 333 ms, and the effects of increased exposure time and frame summing on image contrast and SNR were evaluated. The performance analyses show that TRL microscopy is sufficiently sensitive and precise to allow high‐resolution, quantitative imaging of lanthanide luminescence in living cells under physiologically relevant experimental conditions. © 2010 International Society for Advancement of Cytometry.
📜 SIMILAR VOLUMES
Tissue and cell examinations have a potential to produce extremely valuable information about antigen quantities in samples. Using currently available methods, a truly quantitative analysis is nearly impossible. We have previously shown that immunohistochemical (IHC) detection of prostate-specific a
The presented setup for singlet oxygen luminescence detection in cell suspensions outperforms the current setups by more than one order-of-magnitude gain in sensitivity. This not only allows precise determination of the singlet oxygen lifetime in cells but also reveals a previously unnoticeable beha
This paper describes a rapid and simple method for obtaining epon-embedded specimens for light and electron microscopy from a cell monolayer grown on a culture dish. The cells are washed and fixed in situ with glutaraldehyde, post-fixed with osmium tetroxide, and dehydrated in a series of ethanol. A