✦ Synopsis


Abstract

An enhancement to Dixon's technique is described which can provide error‐free decomposition of water and fat proton images even in the presence of off‐resonance conditions which result from susceptibility differences, demagnetization, or shim errors. The method uses three measurements with phase shifts of 0, π and − π between the fat and water resonances. The additional information provided by the third measurement is used to calculate an image of the field inhomogeneity in addition to true water and fat images. The signal‐to‐noise ratio (SNR) in the decomposed images is equivalent to that of a 2.7 NEX acquisition (instead of 3 NEX), yielding an SNR imaging efficiency of 95%. In addition, the B~0~ image which is provided may have diagnostic value in its own right. Examples of head and body scans often portray surprisingly large B~0~ shifts near interfaces between air or bone and soft tissue. © 1991 Academic Press. Inc.


📜 SIMILAR VOLUMES


Two-point Dixon technique for water-fat
✍ Bernard D. Coombs; Jerzy Szumowski; William Coshow 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 801 KB

## Abstract To separate water and lipid resonance signals by phase‐sensitive MRI, a two‐point Dixon (2PD) reconstruction is presented in which phase‐unwrapping is used to obtain an inhomogeneity map based on only in‐phase and out‐of‐phase image data. Two relaxation‐weighted images, a “water image”

Separation of fat and water in fast spin
✍ Peter A. Hardy; R. Scott Hinks; Jean A. Tkach 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 555 KB

## Abstract A method for suppressing fat in fast spin‐echo imaging with the three‐point Dixon technique is described. The method differs from the three‐point Dixon method used in conventional spin‐echo imaging in that the readout gradient instead of a radio‐frequency pulse is shifted. This method p

Breath-hold water and fat imaging using
✍ Jingfei Ma 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 199 KB

## Abstract A two‐point Dixon technique using a novel phase‐correction algorithm and commercially available dual‐echo fast gradient‐echo pulse sequence is presented. The phase‐correction algorithm determines the directional rather than phase distribution of signals due to field inhomogeneities. Spe