๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

The Voxel Sensitivity Function in Fourier Transform Imaging: Applications to Magnetic Resonance Angiography

โœ Scribed by Dennis L. Parker; Yiping P. Du; Wayne L. Davis


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
888 KB
Volume
33
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

โœฆ Synopsis


Abstract

In this paper the problem of small structure visualization in magnetic resonance imaging (MRI) is considered. The relationship between the structure and the image intensities is defined in terms of the voxel sensitivity function (VSF). Using the VSF, the spatial dependence of the voxel signal for small spheres and cylinders is computed. Although the spatial fluctuation is smaller in the MRI VSF than that which would be obtained from a uniformly sensitive cubical voxel, the deviation still results in significant signal loss near the edges and corners of the voxels. Finally, the VSF formalism is used to demonstrate the improvement in signal uniformity that can be obtained by using zeroโ€filled (bandโ€limited or sinc) interpolation.


๐Ÿ“œ SIMILAR VOLUMES


Functional magnetic resonance imaging in
โœ Jaivijay Ramu; Kurt H. Bockhorst; Kishore V. Mogatadakala; Ponnada A. Narayana ๐Ÿ“‚ Article ๐Ÿ“… 2006 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 484 KB

## Abstract Functional MRI (fMRI) on spinal cordโ€injured rodents at 4 and 8 weeks post injury (PI) is described. The paradigm for fMRI, based on electrical stimulation of rat paws, was automated using an inโ€house designed microprocessorโ€based controller that was interfaced to a stimulator. The MR i

Role of high resolution in magnetic reso
โœ Ramesh Venkatesan; E. Mark Haacke ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 366 KB ๐Ÿ‘ 2 views

The role of high-resolution imaging has generally been discernible in the image. The use of this concept holds potential limited because of the associated loss of signal-to-noise ratio (SNR) for defining the appropriate imaging parameters to allow an object as voxel size decreases and imaging time i

Reliability and sensitivity to change of
โœ Espen A. Haavardsholm; Mikkel ร˜stergaard; Bo J. Ejbjerg; Nils P. Kvan; Till A. U ๐Ÿ“‚ Article ๐Ÿ“… 2005 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 198 KB ๐Ÿ‘ 2 views

## Abstract ## Objective To assess the intraโ€ and interreader reliability and the sensitivity to change of the Outcome Measures in Rheumatology Clinical Trials (OMERACT) Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) system on digital images of the wrist joints of patients with ear

The sensitivity of magnetic resonance im
โœ Seiji Ogawa; T. M. Lee; Bertrand Barrere ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 655 KB

## Abstract The sensitivity of magnetic resonance image signals of the brain to the change in the cerebral blood oxygenation was measured in gradient echo images of rat brains at a field strength of 7 T. The sensitivity depended on the blood vessel volume relative to the tissue volume within the im