Comprehensive and accurate measurements of the saturated-liquid and saturated-vapour densities together with the vapour pressure of pure nitrogen were carried out from the temperature T = 64 K (triple-point temperature Tt = 63.151 K) to 0.022 K below the critical temperature. The typical values of t
The vapour pressure of liquid nitrogen
โ Scribed by M.R. Moussa; R. Muijlwijk; H. Van Dijk
- Publisher
- Elsevier Science
- Year
- 1966
- Weight
- 808 KB
- Volume
- 32
- Category
- Article
- ISSN
- 0031-8914
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
## ยดลฝ . New vapour pressure data for cyclopropane c-C H were obtained in the temperature 3 6 range from 170 K to 225 K. The experimental data were fitted with an equation of the type . . 2 2 ลฝ . ลฝ . ลฝ . ลฝ . ลฝ . ln prkPa s A q Br TrK q C TrK q D T rK , yielding A s 3.70 " 2.13 , B s . y2 . y4 ลฝ . ลฝ
Techniques are discussed whereby liquid helium consumption can be reduced by extension of the range of use of nitrogen. The vapour pressure-temperature relationship has been determined for commercial high-purity nitrogen from the triple point down to 45 K; this data conforms to the expression IogloP
The vapour pressure of liquid D2S and the difference between the vapour pressures of liquid H2S and D2S have been measured at 22 temperatures in the T = (193 to 230) K range. The vapour pressure data, corrected to 100 per cent isotopic purity, have been fitted with the equation: (T/K)โขlnr = -29.385