๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

The value of measuring intravascular platelet aggregates in the prediction of postoperative pulmonary dysfunction

โœ Scribed by C. N. McCollum; I. T. Campbell


Publisher
John Wiley and Sons
Year
1979
Tongue
English
Weight
546 KB
Volume
66
Category
Article
ISSN
0007-1323

No coin nor oath required. For personal study only.

โœฆ Synopsis


Summary

A modified Swank screen filter technique was used to investigate, first, whether intravascular platelet aggregates (IPA) could be detected in patients immediately after surgery and then, the relationship between IPA levels and postoperative pulmonary function. The test, as modified, achieved an excellent reproducibility (r = 0ยท95) and a close correlation with the number of aggregates identified in samples of femoral vein blood by subsequent scanning electron microscopy (r = 0ยท93).

In 20 patients IPA levels were measured 30 min and 3 h after surgery and pulmonary function (arterial Po2, physiological dead space and alveolar/arterial Po2 gradient) was evaluated preoperatively and on days 1 and 7 postoperatively. Patients with elevated IPA levels suffered a greater mean fall in arterial Po2 at 7 days (1ยท8 kPa) than did patients with normal IPA levels (0ยท6 kPa) (P < 0ยท05). This was explained by a marked increase in the pulmonary arteriovenous shunt as indicated by the alveolar/arterial Po2 gradient (2ยท3 kPa v. 0ยท4 kPa, P < 0ยท01). Those patients with increased pulmonary shunting and arterial hypoxia 1 week after surgery also had a greater fall in the platelet count on the first postoperative day.

The screen filtration technique is a reproducible test which measures IPA accurately and may be used to predict pulmonary function 1 week later. This suggests that treatment to inhibit IPA may reduce postoperative pulmonary dysfunction.


๐Ÿ“œ SIMILAR VOLUMES


Measurement of the predictive value of s
โœ Avena, Glancarlo ;Blasi, Carlo ;Eeoli, Enrico ;Scoppola, Anna ๐Ÿ“‚ Article ๐Ÿ“… 1981 ๐Ÿ› Springer-Verlag ๐ŸŒ English โš– 457 KB

The method known as Analysis of Concentration (AOC) is proposed as a tool to measure the predictivity of binary data for cover data. The application of AOC to structured tables of oak forests of Central Italy has proved that binary data are more predictive for cover than cover for binary data. The o

Acid citrate dextrose (acd) formula a as
โœ Pasquale Pignatelli; Fabio M. Pulcinelli; Filippo Ciatti; Marzia Pesciotti; Silv ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 302 KB

To evaluate whether the use of ACD Formula A may affect in vitro platelet function, blood samples were obtained from 21 healthy blood donors and anticoagulated in ACD (acid-citrate dextrose, NIH Formula A), Na citrate 3.8%, and K3EDTA. Platelet count, mean platelet volume, and in vitro platelet aggr