## Perfusion -weighted imaging techniques employing blood water protons as an endogenous tracer have poor temporal resolution because each image should be acquired with an adequate spin 'tagging' time. Thus, perfusion-based functional magnetic resonance imaging studies are typically performed on a
The use of super-resolution techniques to reduce slice thickness in functional MRI
✍ Scribed by Ronald R. Peeters; Pierre Kornprobst; Mila Nikolova; Stefan Sunaert; Thierry Vieville; Grégoire Malandain; Rachid Deriche; Olivier Faugeras; Michael Ng; Paul Van Hecke
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 582 KB
- Volume
- 14
- Category
- Article
- ISSN
- 0899-9457
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The problem of increasing the slice resolution of functional MRI (fMRI) images without a loss in signal‐to‐noise ratio is considered. In standard fMRI experiments, increasing the slice resolution by a certain factor decreases the signal‐to‐noise ratio of the images with the same factor. For this purpose an adapted EPI MRI acquisition protocol is proposed, allowing one to acquire slice‐shifted images from which one can generate interpolated super‐resolution images, with an increased resolution in the slice direction. To solve the problem of correctness and robustness of the created super‐resolution images from these slice‐shifted datasets, the use of discontinuity preserving regularization methods is proposed. Tests on real morphological, synthetic functional, and real functional MR datasets have been performed, by comparing the obtained super‐resolution datasets with high‐resolution reference datasets. In the morphological experiments the image spatial resolution of the different types of images are compared. In the synthetic and real fMRI experiments, on the other hand, the quality of the different datasets is studied as function of their resulting activation maps. From the results obtained in this study, we conclude that the proposed super‐resolution techniques can both improve the signal‐to‐noise ratio and augment the detectability of small activated areas in fMRI image sets acquired with thicker slices. © 2004 Wiley Periodicals, Inc. Int J Imaging Syst Technol 14, 131–138, 2004; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/ima.20016
📜 SIMILAR VOLUMES
## Abstract Children with advanced solid tumours at the Royal Alexandra Hospital for Children (RAHC) receive an intensive four drug chemotherapy combination, Super‐VAC (cyclophosphamide, 500 mg/m^2^, adriamycin, 30 mg/m^2^, actinomycin‐D, 0.5 mg/m^2^, all daily for 3 days, and vincristine, 1.5 mg/m
Gadolinium-enhanced dynamic magnetic resonance (MR) imaging is playing an increasingly important diagnostic role in patients with breast cancer. Because of the multi-focal nature of the disease, it is mandatory to cover all of both breasts, not only in the initial scan, but also at subsequent follow
## Abstract ## Purpose To evaluate the effects of the application of the BLADE (Siemens, Siemens Medical Systems, Erlangen, Germany) technique, a technique to reduce motion artifacts, on navigator‐triggered prospective acquisition correction (PACE) T2‐weighted MRI (T2WI) of the liver. ## Material