𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Usefulness of the application of the BLADE technique to reduce motion artifacts on navigation-triggered prospective acquisition correction (PACE) T2-weighted MRI (T2WI) of the liver

✍ Scribed by Sumire Nanko; Hidekazu Oshima; Takeshi Watanabe; Shigeru Sasaki; Masaki Hara; Yuta Shibamoto


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
367 KB
Volume
30
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To evaluate the effects of the application of the BLADE (Siemens, Siemens Medical Systems, Erlangen, Germany) technique, a technique to reduce motion artifacts, on navigator‐triggered prospective acquisition correction (PACE) T2‐weighted MRI (T2WI) of the liver.

Materials and Methods

Twenty‐three consecutive patients with a total of 57 localized hepatic diseases (39 malignant, 18 benign) and 57 patients without hepatic lesion underwent MR study during eupnea. The images were assessed quantitatively by calculating the liver–lesion contrast. Two subjective analyses were also performed. Two observers independently assessed the image quality and the confidence level of the detection and characterization of hepatic nodules using a five‐point scale. Statistical analysis was performed with the Wilcoxon matched‐pairs test except for the diagnostic performance evaluated with jackknife alternative free‐response receiver operating characteristic (JAFROC) analysis.

Results

There was no significant difference in the mean liver–lesion contrast between the PACE T2WI with BLADE (T2WI‐BLADE) (mean ± SD = 0.29 ± 0.14) and that without BLADE (0.30 ± 0.14) (P = 0.39). Visual assessment of PACE T2WI‐BLADE (4.8 ± 0.47) was superior to that without BLADE (4.3 ± 0.8) (P < 0.0001), although there were no significant differences in detecting and characterizing hepatic lesions using JAFROC analysis.

Conclusion

The BLADE technique could improve image quality by reducing motion artifacts on hepatic MRI without affecting the diagnostic performance. J. Magn. Reson. Imaging 2009;30:321–326. © 2009 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Magnetic resonance imaging of the upper
✍ Christian Klessen; Patrick Asbach; Thomas J. Kroencke; Thomas Fischer; Carsten W 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 342 KB

## Abstract ## Purpose To evaluate a free‐breathing navigator triggered T2‐weighted turbo spin‐echo sequence with prospective acquisition correction (T2w‐PACE‐TSE) for MRI of the upper abdomen in comparison to a conventional T2‐weighted TSE (T2w‐CTSE), a single‐shot TSE (T2w‐HASTE), and a T1‐weigh

High-resolution MR-imaging of the liver
✍ Christoph J. Zech; Karin A. Herrmann; Armin Huber; Olaf Dietrich; Alto Stemmer; 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 533 KB

## Abstract ## Purpose To compare high‐resolution T2‐weigthed images of the liver with and without integrated parallel acquisition techniques (iPAT) using either breath‐hold sequences in combination with prospective acquisition motion correction (PACE) or respiratory triggering. ## Materials and

Motion artifact in T2-weighted fast spin
✍ Kyuran A. Choe; Robert C. Smith; Ken Wilkens; R. Todd Constable 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 981 KB

## Abstract The purpose of our study was to evaluate the effect of respiratory motion on the image contrast of T2‐weighted fast spin‐echo (FSE) images of the liver as well as the reduction of motion artifact using respiratory triggering of the data acquisition. We imaged the livers of 10 healthy vo