Abstract

Quantitative correlations between physicochemical parameters and structure of various solutes and their gas chromatographic behavior were investigated in order to predict the retention values. The identification of unknown samples in gas chromatographic routine analysis of environmental samples is enhanced by the use of these correlations in conjuction with other chromatographic methods and with mass spectrometry. The boiling points of many compounds are easily found in literature and therefore their correlation with retention values obtained in isothermal or programmed temperature analysis permit restriction of the choice of names of unknown compound to within a narrow range. The correlation between the boiling points and the retention times of chloro‐ and bromo‐benzenes and of some chloro‐ and nitro‐ substituted phenols was investigated on non‐polar capillary columns and permitted the tentative identification of many compounds belonging to these homologous series.


📜 SIMILAR VOLUMES


The use of precolumns for solvent focusi
✍ Yan, Zimeng ;Nikelly, John G. 📂 Article 📅 1994 🏛 John Wiley and Sons 🌐 English ⚖ 443 KB 👁 1 views

## Abstract In trace analysis by capillary GC it is often desirable to use larger than normal injection volumes to obtain sufficient sensitivity. This, however, results in a wider solvent peak and tailing, and may reduce column efficiency. This paper describes the use of a short length of a capilla

The effect of the trifluoropropyl group
✍ Dai, Qiong ;Lebrón-Aguilar, Rosa ;Fernández-Sánchez, Elena ;García-Domínguez, Jo 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 426 KB 👁 1 views

## Abstract Four poly(methyl 3,3,3‐trifluoropropyl siloxanes) with trifluoro‐propyl group content (group substitution) between 8 and 35 percent have been synthesized and characterized as stationary phases for gas chromatography in borosilicate glass capillary columns. Results are compared with thos

The use of capillary gas chromatography/
✍ Yvette Michotte; Dirk Deleu; Guy Ebinger 📂 Article 📅 1985 🏛 John Wiley and Sons 🌐 English ⚖ 322 KB 👁 3 views

A capillary gas chromatographichnass spectrometric method was developed for the determination of homovanillic acid and 3,4-dihydroxyphenylacetic acid in discrete areas of human brain known to contain only small amounts of dopamine metabolites. The electron impact mass spectra of the trimethylsilyl d