𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The use of a blood conservation pressure transducer system in critically ill patients

✍ Scribed by S. Thorpe; A. N. Thomas


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
136 KB
Volume
55
Category
Article
ISSN
0003-2409

No coin nor oath required. For personal study only.

✦ Synopsis


We tried to determine if a blood conservation pressure transducer system reduced blood transfusions, increased haemoglobin concentration or reduced line infections in critically ill patients. One hundred patients were randomly allocated to conventional or blood conserving systems attached to systemic and pulmonary arterial catheters. Intravascular lines were cultured after removal. There were no significant differences in transfusions or haemoglobin concentration. Blood conservation: median units transfused, 2 (range 0–19); mean haemoglobin at 7 days, 11.2 g.dl^βˆ’1^ (SD, 1.0). Conventional: median units, 2 (range 0–34); mean haemoglobin at 7 days, 11.1 g.dl^βˆ’1^ (SD 1.0). Thirty‐seven of 99 arterial lines were colonised in the controls compared with 29 of 96 in the blood conservation group. Patients who required haemofiltration in both groups had significantly increased transfusion requirements. Haemofiltration: median 6 units (range 0–34) vs. non‐haemofiltered: median 1 (range 0–14; p < 0.001). There were no significant differences in transfusions, haemoglobin concentration or line colonisation with the blood conservation system. There is considerable potential for blood conservation during haemofiltration.


πŸ“œ SIMILAR VOLUMES


Diagnostic accuracy of a simple ultrasou
✍ A. Scott Keller; Roman Melamed; Michael Malinchoc; Reverly John; David M. Tierne πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 211 KB

## Abstract ## BACKGROUND: Early goal‐directed therapy for severe sepsis or septic shock improves outcomes but requires placement of a central venous catheter to measure central venous pressure (CVP), which may delay timely resuscitation and cause catheter‐related complications. In addition, nonin

A survey of physicians' attitudes to tra
✍ Harsha Boralessa; M. P. Rao; C. Morgan; N. Soni; D. R. Goldhill; S. J. Brett; Ha πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 469 KB

**Summary** We performed a postal survey of Fellows of the Australian and New Zealand College of Anaesthetists with a special interest in obstetric practice, about their beliefs regarding aseptic precautions for insertion of an epidural catheter in the labour ward. Of the 435 consultant anaesthetist

The calibration and use of pressure tran
✍ James R. Hoelscher; William K. Nuttle; Judson W. Harvey πŸ“‚ Article πŸ“… 1993 πŸ› John Wiley and Sons 🌐 English βš– 477 KB

## Abstract The uncertainty in a transducer/tensiometer system was assessed with temperature and pressure calibrations. A reference transducer/tensiometer pair was used to factor out temperature related deviations from two monitoring pairs. The reference pair removed most of the deviations, resulti

A new method for the rapid measurement o
✍ G. L. Hill; I. D. McCarthy; J. P. Collins; A. H. Smith πŸ“‚ Article πŸ“… 1978 πŸ› John Wiley and Sons 🌐 English βš– 444 KB πŸ‘ 2 views

## Abstract A rapid, non-invasive method for the measurement of obsolute amounts of fat, protein, minerals and water in the body has been developed which is applicable to very ill patients. The patients is weighed and skinfold thickness is measured with calipers. The body contents of potassium, nit