The use of a blood conservation pressure transducer system in critically ill patients
β Scribed by S. Thorpe; A. N. Thomas
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 136 KB
- Volume
- 55
- Category
- Article
- ISSN
- 0003-2409
No coin nor oath required. For personal study only.
β¦ Synopsis
We tried to determine if a blood conservation pressure transducer system reduced blood transfusions, increased haemoglobin concentration or reduced line infections in critically ill patients. One hundred patients were randomly allocated to conventional or blood conserving systems attached to systemic and pulmonary arterial catheters. Intravascular lines were cultured after removal. There were no significant differences in transfusions or haemoglobin concentration. Blood conservation: median units transfused, 2 (range 0β19); mean haemoglobin at 7 days, 11.2βg.dl^β1^ (SD, 1.0). Conventional: median units, 2 (range 0β34); mean haemoglobin at 7 days, 11.1βg.dl^β1^ (SD 1.0). Thirtyβseven of 99 arterial lines were colonised in the controls compared with 29 of 96 in the blood conservation group. Patients who required haemofiltration in both groups had significantly increased transfusion requirements. Haemofiltration: median 6 units (range 0β34) vs. nonβhaemofiltered: median 1 (range 0β14; pβ<β0.001). There were no significant differences in transfusions, haemoglobin concentration or line colonisation with the blood conservation system. There is considerable potential for blood conservation during haemofiltration.
π SIMILAR VOLUMES
## Abstract ## BACKGROUND: Early goalβdirected therapy for severe sepsis or septic shock improves outcomes but requires placement of a central venous catheter to measure central venous pressure (CVP), which may delay timely resuscitation and cause catheterβrelated complications. In addition, nonin
**Summary** We performed a postal survey of Fellows of the Australian and New Zealand College of Anaesthetists with a special interest in obstetric practice, about their beliefs regarding aseptic precautions for insertion of an epidural catheter in the labour ward. Of the 435 consultant anaesthetist
## Abstract The uncertainty in a transducer/tensiometer system was assessed with temperature and pressure calibrations. A reference transducer/tensiometer pair was used to factor out temperature related deviations from two monitoring pairs. The reference pair removed most of the deviations, resulti
## Abstract A rapid, non-invasive method for the measurement of obsolute amounts of fat, protein, minerals and water in the body has been developed which is applicable to very ill patients. The patients is weighed and skinfold thickness is measured with calipers. The body contents of potassium, nit