𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The role of whole blood in thrombin generation in contact with various titanium surfaces

✍ Scribed by Andreas Thor; Lars Rasmusson; Ann Wennerberg; Peter Thomsen; Jan-Michael Hirsch; Bo Nilsson; Jaan Hong


Publisher
Elsevier Science
Year
2007
Tongue
English
Weight
594 KB
Volume
28
Category
Article
ISSN
0142-9612

No coin nor oath required. For personal study only.

✦ Synopsis


Understanding of the thrombotic response (activation of the intrinsic coagulation system followed by platelet activation) from blood components upon contact with a titanium dental implant is important and not fully understood. The aims of this study were to evaluate:

(1) the thrombogenic response of whole blood, platelet-rich plasma (PRP) and platelet-poor plasma (PPP) in contact with a highly thrombogenic surface as titanium, (2) the thrombogenic response of clinically used surfaces as hydroxyapatite (HA), machined titanium (mTi), TiO 2 grit-blasted titanium (TiOB) and fluoride ion-modified grit-blasted titanium (TiOB-F). An in vitro slide chamber model, furnished with heparin, was used in which whole blood, PRP or PPP came in contact with slides of the test surfaces. After incubation (60 min rotation at 22 rpm in a 37 1C water bath), blood/plasma was mixed with EDTA or citrate, further centrifuged at +4 1C (2200g at 10 min). Finally, plasma was collected pending analysis. Whole blood in contact with Ti alloy resulted in the binding of platelets to the material surface and in the generation of thrombin-antithrombin (TAT) complexes. With whole blood TAT levels increased 1000-fold compared with PRP and PPP, in which both almost no increase of TAT could be detected. In addition, the platelet activation showed a similar pattern with a 15-fold higher release of b-TG in whole blood. In the in vitro chamber model with the clinically relevant materials, the fluoride-modified surface (TiOB-F) showed pronounced TAT generation compared with TiOB, mTi and HA. Similar results were achieved for platelet consumption and activation markers of the intrinsic coagulation system. Taken together these results implicates first that whole blood is necessary for sufficient thrombin generation and platelet activation during placement of implants. Second, a fluoride ion modification seems to augment the thrombogenic properties of titanium.


πŸ“œ SIMILAR VOLUMES


Surface-attached PEO in the form of acti
✍ Jonas Andersson; Fredrik Bexborn; Jeanna Klinth; Bo Nilsson; Kristina Nilsson Ek πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 205 KB

## Abstract In the present work we have bound Pluronicβ„’, a class of triblock copolymers consisting of a block of polypropylene oxide (PPO) surrounded on each side by polyethylene oxide (PEO) blocks, to polystyrene surfaces and investigated the thrombogenicity and complement activation of this const