To date, there are two fairly well-established alternatives for laserinduced shock-wave lithotripsy in clinical practice. The Q-switched Nd:YAG laser is distinguished by the high-stone selectivity of its coupler systems. The necessity of a coupler system and its fairly small conversion rate of light energy into mechanical energy present serious drawbacks. Furthermore, the minimal outer diameter of the transmission system is 1.8 mm.

The pulsed-dye laser can be used with a highly flexible and uncomplicated 200-pm fiber. However, the laser system itself is more complicated than the Q-switched Nd:YAG laser and requires a great deal of maintenance. Biological evaluation of damage caused by direct irradiation shows that both laser systems produce minor damage of different degrees.

YAG laser lithotripsy with the optomechanical coupler was assessed in 31 patients with ureteral calculi. The instability and limited effectiveness of the fiber application system necessitated auxiliary lithotripsy methods in 14 cases. Dye-laser lithotripsy is currently being tested in clinical application.

Further development, such as systems for blind application or electronic feedback mechanisms to limit adverse tissue effects, have yet to be optimized.

Nevertheless, laser-induced shock-wave lithotripsy has the potential to become a standard procedure in the endourologic management of stone disease.


📜 SIMILAR VOLUMES


Minocycline-induced hyperpigmentation: T
✍ Greve, Baerbel; Schönermark, Matthias P.; Raulin, Christian 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 238 KB 👁 2 views

## Background and objective: Cutaneous hyperpigmentations are well-documented, but nevertheless rare side-effects of high-dose or long-term minocycline therapy. the pigmental changes, may last for years, even though therapy has been abrogated. to date, no safe and effective therapy has been describ

Q-switched ruby versus long-pulsed dye l
✍ Taro Kono; Dieter Manstein; Henry H. Chan; Motohiro Nozaki; R. Rox Anderson 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 150 KB 👁 1 views

## Abstract ## Background and Objectives Q‐switched lasers have been used for the treatment of lentigines but post‐inflammatory hyperpigmentation (PIH) can be an issue especially in Asians. The 595 nm long‐pulsed dye laser (LPDL) has been used for the treatment of vascular lesions and although it

Comparison study of a traditional pulsed
✍ Taro Kono; Hiroyuki Sakurai; William Frederick Groff; Henry H. Chan; Masaki Take 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 82 KB

## Abstract ## Background and Objective The role of pulsed dye laser (PDL) in the treatment of childhood hemangiomas is still controversial because of the inherent characteristics of hemangiomas as well as the side effects of the PDL. Recently, the long pulsed dye laser (LPDL) with cryogen spray c

In vivo trial comparing patients' tolera
✍ Chan, Henry H.L.; King, Walter W.K.; Chan, Eric S.Y.; Mok, Chun On; Ho, Wai Sun; 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 58 KB 👁 2 views

## Background and Objectives : Different types of Q-switched lasers have been found to be effective in the treatment of nevus of Ota. However, a clinical trial involving in vivo comparison of the use of different laser systems has not been performed. The aim of the present study was to compare the

Intracranial pressure waves generated by
✍ Czurkó, András; Tóth, Zsolt; Dóczi, Tamás; Gallyas, Ferenc 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 903 KB

Background and Objective: Histological effects of 2.1-m Ho:YAG and 1.06-m Nd:YAG laser pulses were compared in the rat brain, with special regard to areas remote from the irradiated site. Study Design/Materials and Methods: Laser pulses were delivered through a 0.6-mm glass fiber, the tip of which w