𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The preparation of thick-film glass capillary columns

✍ Scribed by Torline, P. ;du Plessis, G. ;Schnautz, N. ;Thompson, J. C.


Publisher
John Wiley and Sons
Year
1979
Tongue
English
Weight
354 KB
Volume
2
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A detailed method for the routine preparation of glass capillary columns is presented. The method consists of coating a glass tube with quartz powder prior to pulling the tube into a capillary. The inner surface of the capillary consists of an even distribution of quartz particles fused to the walls. This surface has been found readily deactivated by standard procedures and ideal for the preparation of thick‐film glass capillary columns. The method has been thoroughly tested in two independent laboratories to ensure that the procedures described are reproducible.


πŸ“œ SIMILAR VOLUMES


Preparation of small diameter thick film
✍ Dirk Steenackers; Pat Sandra πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 497 KB

## Abstract Open tubular columns of 25 and 50 ΞΌm i.d. have been coated with up to 2 ΞΌm thick layers of SE‐54 (lowest β‐value = 6.25). Filling of the columns and evaporation of the solvent were studied as a function of column length and time. Since the viscosity of the stationary phase solution incr

Effect of film thickness on the selectiv
✍ Leonard M. Sidisky; Jacques A. Rijks πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 348 KB

## Abstract Data presented herein show that the film thickness of a polar stationary phase, SP‐2380, affects column selectivity under isothermal analysis conditions. The expected linear relationship between film thickness and solute capacity factors (k), as predicted by the partition coefficient eq

On the efficiency of capillary columns c
✍ David, F. ;Proot, M. ;Sandra, P. πŸ“‚ Article πŸ“… 1985 πŸ› John Wiley and Sons 🌐 English βš– 435 KB πŸ‘ 1 views

The efficiency of FSOT columns coated with thick films of polyphenylmethylsiloxane was theoretically and experimentally compared to thin apolar and medium polar coatings and to thick apolar coatings. Experimental hli and TZG plots clearly demonstrate the enormous loss in chromatographic efficiency o

Evaluation of graphitized glass capillar
✍ Goretti, G. ;Liberti, A. ;Pili, G. πŸ“‚ Article πŸ“… 1978 πŸ› John Wiley and Sons 🌐 English βš– 329 KB

## Abstract The performance of graphitized glass capillary columns obtained by precoating the inner glass walls with graphitized carbon black has been evaluated. It has been shown that according to the amount of stationary phase coated such columns can operate in gas–liquid‐solid chromatography and