𝔖 Bobbio Scriptorium
✦   LIBER   ✦

On the efficiency of thick film capillary columns

✍ Scribed by Sandra, P. ;Temmerman, I. ;Verstappe, M.


Publisher
John Wiley and Sons
Year
1983
Tongue
English
Weight
252 KB
Volume
6
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


On the efficiency of capillary columns c
✍ David, F. ;Proot, M. ;Sandra, P. πŸ“‚ Article πŸ“… 1985 πŸ› John Wiley and Sons 🌐 English βš– 435 KB πŸ‘ 1 views

The efficiency of FSOT columns coated with thick films of polyphenylmethylsiloxane was theoretically and experimentally compared to thin apolar and medium polar coatings and to thick apolar coatings. Experimental hli and TZG plots clearly demonstrate the enormous loss in chromatographic efficiency o

The preparation of thick-film glass capi
✍ Torline, P. ;du Plessis, G. ;Schnautz, N. ;Thompson, J. C. πŸ“‚ Article πŸ“… 1979 πŸ› John Wiley and Sons 🌐 English βš– 354 KB πŸ‘ 1 views

## Abstract A detailed method for the routine preparation of glass capillary columns is presented. The method consists of coating a glass tube with quartz powder prior to pulling the tube into a capillary. The inner surface of the capillary consists of an even distribution of quartz particles fused

Effect of film thickness on the selectiv
✍ Leonard M. Sidisky; Jacques A. Rijks πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 348 KB

## Abstract Data presented herein show that the film thickness of a polar stationary phase, SP‐2380, affects column selectivity under isothermal analysis conditions. The expected linear relationship between film thickness and solute capacity factors (k), as predicted by the partition coefficient eq

Preparation of small diameter thick film
✍ Dirk Steenackers; Pat Sandra πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 497 KB

## Abstract Open tubular columns of 25 and 50 ΞΌm i.d. have been coated with up to 2 ΞΌm thick layers of SE‐54 (lowest β‐value = 6.25). Filling of the columns and evaporation of the solvent were studied as a function of column length and time. Since the viscosity of the stationary phase solution incr

Effect of film thickness and supercoolin
✍ Heath, R. R. ;Jordan, J. R. ;Sonnet, P. E. πŸ“‚ Article πŸ“… 1981 πŸ› John Wiley and Sons 🌐 English βš– 369 KB πŸ‘ 1 views

## Abstract Improved separations of the isomers of olefinic aliphatic insect pheromones were obtained on cholesteryl cinnamate glass capillary columns by operating in the supercooled temperature range of the liquid crystal. Capillary columns were prepared with varying film thickness of the stationa

Effect of stationary phase film thicknes
✍ Fields, S. M. ;Kong, R. C. ;Lee, M. L. ;Peaden, P. A. πŸ“‚ Article πŸ“… 1984 πŸ› John Wiley and Sons 🌐 English βš– 421 KB πŸ‘ 1 views

Fused-silica capillary columns with internal diameters of 50 pm were coated with 0.25 to 1.0 pm films of SE-54 and evaluated under supercritical fluid chromatographic conditions using carbon dioxide as mobile phase. Experimental results compared well with theoretical predictions. There was no signif