## Abstract This report describes a convenient method for the fabrication of a miniaturized, reliable Ag/AgCl reference electrode with nanofluidic channels acting as a salt bridge that can be easily integrated into microfluidic chips. The Ag/AgCl reference electrode shows high stability with milliv
The fabrication and performance of an Ag/AgCl reference electrode in human serum
β Scribed by Pengguang Yu; Shaojun Dong
- Publisher
- Elsevier Science
- Year
- 1996
- Tongue
- English
- Weight
- 593 KB
- Volume
- 330
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
β¦ Synopsis
A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1 .O mol 1-l HCl with a pulse current density of 20 mA cmm2, and the pulse wave parameters of t$t, = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t,) to the working time (t,) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 mol 1-l KC1 was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.
π SIMILAR VOLUMES
The cephalosporin cefepime has been studied by adsorptive stripping voltammetric on the hanging mercury drop electrode, followed by linear sweep voltammetry (staircase). The adsorptive stripping response was evaluated with respect to preconcentration dependence and other variables. The drug is stron
A simple and reliable HPLC method for quantitative determination of pseudouridine and uric acid in human urine and serum using a cation-exchange resin is described. This method is straightfonvard (12 runs of urine samples per day since the sample is only diluted into buffer and then chromatographed)