The fabrication and performance of an Ag/AgCl reference electrode in human serum

✍ Scribed by Pengguang Yu; Shaojun Dong


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
593 KB
Volume
330
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A simple set of electric circuits was used to assemble a pulse generator. With pulse potentials and under galvanostatical control, a clean silver wire was anodized electrochemically for 0.2-0.5 min in 1 .O mol 1-l HCl with a pulse current density of 20 mA cmm2, and the pulse wave parameters of t$t, = 1 and a cycle of 4 s forming an Ag/AgCl reference electrode. Even though the AgCl layer was consumed during the working period when the Ag/AgCl electrode was used as a cathode, the AgCl layer could be in situ recovered electrochemically in serum used when a reversed potential was applied to the electrode system immediately after the measuring program was finished. The current response curve of the anode indicated that an AgCl layer in high density was basically accomplished during the first 6 pulse cycles in human serum. In order to keep a stable and uniform AgCl layer on the reference electrode after each measuring cycle, the ratio of the recovery time (t,) to the working time (t,) was measured and the smallest value was obtained at 0.03. The open-circuit potential of the Ag/AgCl electrode with respect to a SCE in 0.1 mol 1-l KC1 was monitored over a period of 14 days and the mean value was 40.09 mV vs SCE with a standard deviation of 2.55 mV. The potential of the Ag/AgCl reference electrode did remain constant when the measurements were repeated more than 600 times in undiluted human serum with a standard deviation of 1.89 mV. This study indicated that the Ag/AgCl reference electrode could been rapidly fabricated with a pulse potential and could be used as a reference electrode with long-term stable properties in human serum samples.


πŸ“œ SIMILAR VOLUMES


Fabrication of a microfluidic Ag/AgCl re
✍ Jianhua Zhou; Kangning Ren; Yizhe Zheng; Jing Su; Yihua Zhao; Declan Ryan; Hongk πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 193 KB

## Abstract This report describes a convenient method for the fabrication of a miniaturized, reliable Ag/AgCl reference electrode with nanofluidic channels acting as a salt bridge that can be easily integrated into microfluidic chips. The Ag/AgCl reference electrode shows high stability with milliv

Adsorptive stripping voltammetric determ
✍ F.J. JimΓ©nez Palacios; M. CallejΓ³n MochΓ³n; J.C. JimΓ©nez SΓ‘nchez; J. Herrera Carr πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 111 KB

The cephalosporin cefepime has been studied by adsorptive stripping voltammetric on the hanging mercury drop electrode, followed by linear sweep voltammetry (staircase). The adsorptive stripping response was evaluated with respect to preconcentration dependence and other variables. The drug is stron

A high-performance liquid chromatographi
✍ Heinrich Topp; Gernot Sander; Gesa Heller-SchΓΆch; Gerhard SchΓΆch πŸ“‚ Article πŸ“… 1985 πŸ› Elsevier Science 🌐 English βš– 471 KB

A simple and reliable HPLC method for quantitative determination of pseudouridine and uric acid in human urine and serum using a cation-exchange resin is described. This method is straightfonvard (12 runs of urine samples per day since the sample is only diluted into buffer and then chromatographed)