𝔖 Bobbio Scriptorium
✦   LIBER   ✦

The energy stored during the cold working of a gold-silver alloy

✍ Scribed by M.B Bever; L.B Ticknor


Publisher
Elsevier Science
Year
1953
Weight
802 KB
Volume
1
Category
Article
ISSN
0001-6160

No coin nor oath required. For personal study only.

✦ Synopsis


Strips of an alloy of 75 wt. per cent gold and 25 wt. per cent silver were cold worked by rolliitg.

The stored energy was released by dissolution of the samples in liquid tin and found calorimetrically by comparison with annealed samples. The total energy expended in rolling was determined from a stress-strain diagram applicable to the rolling process.

The stored energy increases with the strain, but shows a tendency toward saturation at high strains. The ratio of the stored energy to the total energy expended decreases at high strains. L'GNERGIE ACCUMUL6.E PENDANT L%CROUISSAGE DUN ALLIAGE OR-ARGENT D'etroites lamelles d'un alliage de 75 pour cent en poids d'or et de 25 pour cent en poids d'argent, ont et& Ccrouis par laminage. L'energie accumulee a et& lib&e par dissolution des echantillons recuits. L'Cnergie totale depensee lors du laminage a et& determinCe d'un diagramme tension-deformation applicable au laminage. L'Cnergie accumulite augmente avec la deformation, mais montre une tendance B la saturation aux grandes deformations. Le rapport de l'energie accumulee B I'energie totale d&pens&e diminue quand les deformations deviennent importantes. DIE WAHREND DER KALTBEARBEITUNG EINER GOLD-SILBER-LEGIERUNG GESPEICHERTE ENERGIE Bander einer Legierung von 75 Gew. prozent Gold und 25 Gew. prozent Silber wurden durch. Walzen kalt verformt. Die aufgespeicherte Energie wurde durch Auflosen der Proben in fltissigem Zinn frei gemacht und kalorimetrisch durch Vergleich mit geghihten Proben bestimmt. Die gesamte wahrend des Walzens aufgewandte Energie wurde aus der auf den Walzvorgang anwendbaren Verz&rungs-Spannungs-Kurve bestimmt. Die aufgespeicherte Energie wachst mit wachsender Verzerrung, zeigt jedoch eine deutliche Tendenz zur Absattigung bei grossen Verzerrungen. Das Verhaltnis der aufgespeicherten Energie zur gesamten aufgewandten Energie nimmt bei grosseren Verzefrungen ab.


πŸ“œ SIMILAR VOLUMES


The effect of composition on the stored
✍ P Greenfield; M.B Bever πŸ“‚ Article πŸ“… 1957 πŸ› Elsevier Science βš– 716 KB

The energy stored in chips formed by drilling at room temperature and at -195Β°C has been determined for five gold-silver alloys in the composition range from 35 to 98 atomic per cent Au. The stored energy varies with composition by a factor of nearly 5 at room temperature and by nearly 3 at -195Β°C.

The evolution of the energy stored by a
✍ Peter Greenfield; M.B. Bever πŸ“‚ Article πŸ“… 1956 πŸ› Elsevier Science βš– 758 KB

Thr energy storctl in an S2.6 gold-17.4 silvpr (b>-weight) alloy, cold-worked at -1% C and al 1'00nt t cmprratwe, ha,s been measured by tin-solution calorimetry. The effect, of nwlealing upon the rue~p>-cw>tnlt retained by samples deformed at t,hese trmperat~ures has been investigated. The stored el

Relation of the stored energy of cold wo
✍ David L. Holt πŸ“‚ Article πŸ“… 1965 πŸ› Elsevier Science βš– 237 KB

6oyc 75yc 709% \ 65yC --ITF l4'Z+PF , l39o'F 1290'F' 10-S ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' 0.90 0.95 1.0 1.05 do-'" 1000/T FIN. 3. The stress-dependent multiplication and immobilization rate constants at 13,190 psi showing that they vary similarly with temperature as the steady state creep rate

X-ray and calorimetric investigations of
✍ B.L Averbach; M.B Bever; M.F Comerford; J.S.Li Leach πŸ“‚ Article πŸ“… 1956 πŸ› Elsevier Science

Calorimetric and X-ray diffraction line-broadening measurements were carried out on samples of a 75Au-25Ag (weight per cent) alloy deformed by filing and annealed at various temperatures up to 500Β°C. Stored energy, hardness, subgrain size, local strain, and short-range order determinations were made

The stored energy of cold work and its r
✍ A.L Titchener; M.B Bever πŸ“‚ Article πŸ“… 1960 πŸ› Elsevier Science βš– 632 KB

One set of wires of an 82.6 Au-17.4 Ag (wt.%) alloy was drawn at -195Β°C to a true strain of 0.62. A second set, after drawing at -195Β°C to a strain of 0.62, was annealed at room temperature. Two further sets were drawn at -195Β°C to a strain of 0.62, brought to room temperature and drawn to total st