๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

The effect of operating parameters in the Stirling cryocooler

โœ Scribed by S.J. Park; Y.J. Hong; H.B. Kim; D.Y. Koh; J.H. Kim; B.K. Yu; K.B. Lee


Book ID
104112277
Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
536 KB
Volume
42
Category
Article
ISSN
0011-2275

No coin nor oath required. For personal study only.

โœฆ Synopsis


This paper presents design, manufacturing process and test results in the optimum operating condition for the free piston free displacer (FPFD) type Stirling cryocooler designed and manufactured by Korea Institute of Machinery and Materials. FPFD Stirling cryocooler is currently under development for cooling infrared detector. The compressor in the Stirling cryocooler uses opposed linear motors to drive opposed pistons. The performance of FPFD Stirling cryocooler is evaluated as a function of charging pressure and operating frequency. In general, as the charging pressure is increased, optimum-operating frequency of the compressor is increased but resonant frequency of the displacer is almost constant. The prototype has achieved no load temperature of 49 K and cooling power of 0.5 W at 72 K.


๐Ÿ“œ SIMILAR VOLUMES


Parity simulation of thermoacoustic effe
โœ Y. Xiang; B. Kuang; F.Z. Guo ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 651 KB

The thermally induced acoustic effect occurring in a regenerator with a temperature gradient has been observed on a particularly built regenerator experimental set-up attached to a Stirling cryocooler system. To describe this thermoacoustic phenomenon, a parity simulation network model has been esta

A study on the linear compressor charact
โœ Deuk-Yong Koh; Yong-Ju Hong; Seong-Je Park; Hyo-Bong Kim; Kwan-Soo Lee ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 307 KB

The purpose of this study is to analyze the characteristics of the linear compressor for Stirling cryocooler. To ensure high performance and long life of the free piston, free displacer Stirling cryocooler, the operating parameters of the linear compressor should be optimized. The experimental resul

EFFECT OF SOLAR COLLECTOR DESIGN PARAMET
โœ Narendra Singh; B. M. Gibbs; S. C. Kaushik ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 163 KB ๐Ÿ‘ 2 views

An analysis has been carried out to find out the optimum operating temperature for solar Stirling power systems. The analysis has also clearly brought out the effect of solar collector design parameters, such as, concentration ratio, overall heat loss coefficient, and heat engine parameter on the ov