## Abstract Patellofemoral dysfunction following total knee replacement (TKR) is a significant clinical problem, but little information exists on the mechanics of the patellofemoral retinacula or the effects of TKR on these structures. We hypothesized that TKR would cause significant elongation of
The effect of femoral component rotation on the extensor retinaculum of the knee
β Scribed by Kanishka M. Ghosh; Azhar M. Merican; Farhad Iranpour; David J. Deehan; Andrew A. Amis
- Publisher
- Elsevier Science
- Year
- 2010
- Tongue
- English
- Weight
- 194 KB
- Volume
- 28
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Malrotation of the femoral component may cause patellofemoral complications after total knee replacement (TKR). We hypothesized that femoral component malrotation would cause excessive lengthening of the retinacula. Retinacular length changes were measured by threading fine sutures along them and attaching these to the patella and to displacement transducers. The knee postβTKR was flexedβextended while the quadriceps were tensed, then the measurements repeated after rotating the femoral component 5Β° internally and then 5Β° externally. Internal rotation shortened the medial patellofemoral ligament (MPFL) significantly from 100Β° to 0Β° extension. External rotation lengthened the MPFL significantly from 90Β° to 0Β° extension. The transverse fibers of the lateral retinaculum showed no significant differences. The MPFL attaches directly from bone to bone, so it was lengthened directly by movement of the trochlea and patella, whereas the deep transverse fibers of the lateral retinaculum attach to the mobile iliotibial tract, so they were not lengthened directly. Β© 2010 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:1136β1141, 2010
π SIMILAR VOLUMES
## Abstract The ultrastructure of the femoral extensors of the metathoracic leg of the cockroach, __Periplaneta americana__ was studied to determine morphological correlations with the known patterns of innervation, physiological properties and biochemical properties. Three different types of muscl
Initial rigid fixation is essential for bone ingrowth into a porous-coated prosthesis. In this study, the amount of micromotion between a cut tibial surface and a custom tibial baseplate mounted with various types of screw fixation was measured. Motion transducers were placed at the corners of the b
## Abstract Highβflexion knee replacements have been developed to accommodate a large range of motion (RoMβ>β120Β°). Knee implants that allow for higher flexion may be more sensitive to femoral loosening as the knee load is relatively high during deep knee flexion, which could result in an increased