𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Does high-flexion total knee arthroplasty promote early loosening of the femoral component?

✍ Scribed by Jorrit Zelle; Dennis Janssen; Jolanda Van Eijden; Maarten De Waal Malefijt; Nico Verdonschot


Publisher
Elsevier Science
Year
2011
Tongue
English
Weight
646 KB
Volume
29
Category
Article
ISSN
0736-0266

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

High‐flexion knee replacements have been developed to accommodate a large range of motion (RoM > 120°). Knee implants that allow for higher flexion may be more sensitive to femoral loosening as the knee load is relatively high during deep knee flexion, which could result in an increased failure potential at the implant–cement interface of the femoral component. A 3D finite element knee model was developed including a posterior‐stabilized high‐flexion knee replacement to analyze the stress state at the femoral implant–cement interface during a full squatting movement (RoM ≤ 155°). During deep flexion (RoM > 120°), tensile and shear stress concentrations were found at the implant–cement interface beneath the proximal part of the anterior flange. Particularly, the shear stresses at this interface location increased during high flexion, from a peak stress of 4.03 MPa at 90° to 6.89 MPa at 140° of flexion. Tensile stresses were substantially lower, having a peak stress of 0.72 MPa at 100° of flexion. Using data from earlier interface strength experiments, none of the interface beneath the anterior flange was predicted to fail in the normal flexion range (RoM ≤ 120°), whereas the prediction increased to 2.2% of the interface during deeper knee flexion. Thigh‐calf contact reduced the knee forces, interface load, and failure risk beyond 140–145° of flexion. Based on the more critical stresses at the femoral fixation site between 120° and 145° of flexion, we conclude that the femoral component has a higher risk of loosening at high‐flexion angles. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 29: 976–983, 2011


📜 SIMILAR VOLUMES


Femoral component migration in total kne
✍ Kjell G. Nilsson; Johan Kärrholm; Lars Linder 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 972 KB

The Miller-Galante I knee replacement was inserted in 25 women and three men (33 knees) with osteoarthrosis. All patients received a TiAlV femoral component with a commercially pure titanium fiber-mesh undersurface. Cemented or cementless fixation was used based on a randomization protocol. Micromot