Fracture site axial rigidity was monitored nondestructively at weekly intervals during healing of tibia1 osteotomies in adult rabbits. Two groups of 20 rabbits each were treated with external fixators of two different rigidities. Four animals from each group were killed at 3, 5 , 6, 7, and 8 weeks t
The effect of external fixation stiffness on early healing of transverse osteotomies
β Scribed by Dr. Jerome A. Gilbert; Laurence E. Dahners; Melissa A. Atkinson
- Publisher
- Elsevier Science
- Year
- 1989
- Tongue
- English
- Weight
- 790 KB
- Volume
- 7
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
The effect of bending stiffness of external fixators on the early healing of transverse tibial osteotomies was studied in a canine model to determine whether there is a particular range of fixation stiffness where healing is poor. Five unilateral fixators with different stiffnesses were developed and employed along with a dynamic compression plate to fix experimental osteotomies of dog tibias and the contralateral intact tibias served as controls. The six experimental fixation devices were: plate (P), stainless steel sidebar fixator (SS), stiff aluminum sidebar fixator (SA), intermediate aluminum sidebar fixator (IA), flexible aluminum sidebar fixator (FA), and Delrin sidebar fixator (D). Compared with human tibial fixation methods, the fixators ranged from a rigidity greater than a plate on a human tibia to a flexibility similar to a plaster cast on a human lower leg. Sixty-four adult male mongrel dogs (29 * 3 kg) underwent surgery and 52 completed the 9-week study, leaving 7 to 10 dogs in each experimental group (P = 8, SS = 7, SA = 9, IA = 9, FA = 10, D = 9).
After the 9-week survival period the experimental tibias were radiographed and callus area was digitized. Both the experimental and control tibias were then tested to failure in four-point bending, and failure moment, stiffness, and energy to failure were determined. Of the 52 osteotomies, only four developed nonunions: 3 of 10 in the FA group and 1 of 7 in the SS group. Using analysis of variance, no statistical differences were detected in failure force, stiffness, or energy to failure as a function of fixator groups. The mean callus area in the most flexible fixation group (D) was significantly greater than that in the P, SS, and IA groups.
π SIMILAR VOLUMES
## Abstract Osteotomy of the rat femur performed by the laser was compared to osteotomty made by a handβsaw cut. It was noted that, radiographically and histologically, there was a delay in healing in the laser group, but biomechanical testing failed to reveal any significant difference in bone str
In order to throw some light on the controversial issue of the optimal stiffness in fracture fixation, the effects on bone healing of rabbit tibial osteotomies fixed by plates with four different degrees of stiffness were studied. The least stiff plate was made of glass fiber-reinforced epoxy; the o
Sixty-nine male Sprague Dawley rats were divided into three groups of 23 animals each and osteotomies were performed in group 1 with a power saw, in group 2 with the Erb:Yag laser, and in group 3 with the Ho1:YAG laser. Two animals of each group were sacrificed 1 week, 4, 8, and 12 weeks after opera
## Abstract Fracture healing is a complex process, which is more complicated if the bone is osteoporotic. One of the vitamin E isomers, Ξ±βtocopherol, has been found to prevent osteoporosis and improve bone fracture healing but its role in the healing of osteoporotic fractures is still unclear. We c