The effect of capillary column diameter on the performance of thermal conductivity detectors
β Scribed by Blumberg, Leonid M. ;Dandeneau, Raymond D.
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 817 KB
- Volume
- 18
- Category
- Article
- ISSN
- 0935-6304
No coin nor oath required. For personal study only.
β¦ Synopsis
The concentration sensitivity of a thermal conductivity detector (TCD) depends, among other factors, on the amount of sample mixture in the detector's sensing cell. Since the cell volume has to be appropriately matched with column diameter, it makes the concentration sensitivity of a TCD dependent on column diameter and, therefore, on the speed of gas chromatography. Through reduction of column diameter, higher speed tends to lead to a reduction in the concentration sensitivity of the cell. The factor which the most directly affects the concentration sensitivity of a TCD cell is the heat power conducted through the cell. The higher the power, the greater the sensitivity. The limit of detection of a TCD depends on the concentration-sensitivity of its cell and on the level of statistical errors in the measurement. The errors increase with increasing analysis speed. As the column diameter is reduced, the errors cause additional worsening (on top of the decrease in concentration sensitivity) of the detection limit, dynamic range, and other performance characteristics of the TCD.
If the cell is filled with sample mixture from a GC column (a mixture of a sample with the carrier gas) then, because of the thermal conductance, A, of the cell and the temperature differ-
π SIMILAR VOLUMES
Fused silica capillary columns with internal diameters from 100 to 25 pm werecoated withSE-54 and evaluated undersupercritical fluid chromatographic conditions using carbon dioxide as mobile phase.Experimental results compared well with theoretical predictions. At ten times the optimum mobile phase
The basic analytical parameters of contactless conductivity detectors with planar, semi-tubular and tubular electrodes have been compared. It has been found that the differences in the analytical parameters of the detectors are not significant for analytical use. The mean values of baseline peak-to-
The effect of W o 7-radiation on the thermal conductivity of polypropylene (PP) has been studied over the temperature range 0-160Β°C. for radiation doses of 600 and 1800 Mrad. The conductivity of unirradiated specimens rises from 4.5 X lo-' cgs units (cal./cm.-sec.-"C.) a t 0Β°C. to 4.8 X cgs units a
Table 1 k-Values of 3-Ethinylcholestan-3a-oles Table 2 k-Values of 3-Ethinylcholestan-3p-oles Mobile Phase') Mobile Phase') R2) I I1 111 Rf 0.30 0.33 0.41 k 2.33 2.03 1.44 Rf 0.57 0.61 0.72 k 0.75 0.64 0.39 H C6H5 0.52 0.61 0.74 0.92 0.64 0.35 R2) I I1 111 Rf 0.12 0.14 0.20 k 7.33 6.1 4 4.00 Rf 0.18