## Abstract Technical grade diethylene‐triaminepentakis(methylenephosphonic acid) (I), dihexamethylene‐triaminepentakis(methylenephosphonic acid) (II), ethylene‐diaminetetrakis(methylenephosphonic acid) (III), hexamethylene‐diaminetetrakis(methylenephosphonic acid) (IV), amino‐tris(methylenephospho
The analysis of industrial synthetic polymers by electrospray droplet impact/secondary ion mass spectrometry
✍ Scribed by Daiki Asakawa; Lee Chuin Chen; Kenzo Hiraoka
- Publisher
- John Wiley and Sons
- Year
- 2009
- Tongue
- English
- Volume
- 44
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.1569
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Electrospray droplet impact (EDI)/secondary ion mass spectrometry (SIMS) is a new desorption/ionization technique for mass spectrometry in which highly charged water clusters produced from the atmospheric‐pressure electrospray are accelerated in vacuum by several kV and impact the sample deposited on the metal substrate. In this study, several industrial synthetic polymers, e.g. polystyrene (PS) and polyethylene glycol (PEG) were analyzed by EDI/SIMS mass spectrometry. For higher molecular weight analytes, e.g. PS4000 and PEG4600, EDI/SIMS mass spectra could be obtained when cationization salts are added. For the polymers of lower molecular weights, e.g. PEG300 and PEG600, they could be readily detected as protonated ions without the addition of cationization agents. Anionized PS was also observed in the negative ion mode of operation when acetic acid was added to the charged droplet. Compared to matrix‐assisted laser desorption/ionization (MALDI), ion signal distribution with lower background signals could be obtained particularly for the low‐molecular weight polymers. Copyright © 2009 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Liquid chromatography/electrospray mass spectrometry with selected-ion monitoring makes possible the visualization and positive identification of a family of isobaric ions from libraries comprising hundreds of peptides. For larger libraries (up to 10 5 peptides), a given peptide, known to be unique
## Abstract It has been suggested in the literature that nano‐electrospray ionization (nano‐ESI) mass spectrometry better reflects the equilibrium between complex and free protein in solution than pneumatically assisted electrospray ionization (ESI) in noncovalent interaction studies. However, no s
The analysis of polymerase chain reaction (PCR) products by electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR) has been achieved. Specifically, a 105 base-pair nucleotide portion of the ribosomal spacer region was amplified in two members of the B. cereus