A laminar jet instrument was used to measure the molecular diffusivities of oxygen with 0.995 partial pressure into distilled water and aqueous solutions of eight long chained polymers. Molecular diffusivity of oxygen into distilled water was found to be 1.95 x 10m5, at 20°C which compares favorabl
The absorption of oxygen by dilute polymeric solutions—molecular diffusivity measurements
✍ Scribed by A. Dim; A.B. Ponter
- Publisher
- Elsevier Science
- Year
- 1971
- Tongue
- English
- Weight
- 69 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0009-2509
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
The objective of this paper is to present a new method of measuring oxygen diffusion coefficients with membrane-covered polarographic oxygen electrodes and to assess its applicability to viscous polymeric solutions of sodium carboxymethylcellulose (CMC), dextran and polyethylene glycol (PEG). The re
Experimental conditions are presented under which the Taylor dispersion technique is capable of generating accurate translational diffusion coefficients for polymers in dilute solutions across a wide temperature range. With the Monte Carlo results on polymethylene conformation, the Kirkwood-Riseman
A simple batch sorption method is examined for diffusivity determinations of binary solutions of low molecular weight organic compounds in amorphous polymers. The method is based on solute uptake from a stirred liquid solution by a polymer sheet sample submerged in the liquid solution and measuremen