๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Testing a measure of image quality for acquisition control

โœ Scribed by J.A. Marchant


Publisher
Elsevier Science
Year
2002
Tongue
English
Weight
309 KB
Volume
20
Category
Article
ISSN
0262-8856

No coin nor oath required. For personal study only.

โœฆ Synopsis


Previous work by the author has shown that the entropy of an image's histogram can be used to control the acquisition variables (brightness, contrast, shutter speed) of a camera/digitiser combination in situations where the imaging conditions are changing. Although the control leads to histograms that satisfy pragmatic expectations of what a `good' histogram should look like (i.e. ยฎlling the dynamic range of the digitiser without too much saturation), it avoids the problem of what we mean by a good histogram in the machine vision context and whether the control produces images that have these histograms.

In this work a good image is deยฎned to be one where the subsequent analysis algorithms work well. Three different algorithms, each containing many diverse components, are tested on sets of images with different acquisition parameters. As well as acquiring at different parameters, a simulation of the image acquisition process is derived and validated to assist evaluation. Test results show that near-optimal performance is obtained with maximum entropy and it is concluded that this measure is a suitable one for control of image acquisition.


๐Ÿ“œ SIMILAR VOLUMES


Automatic Quality Control of Cereals : I
โœ Petra Perner ๐Ÿ“‚ Article ๐Ÿ“… 2008 ๐Ÿ› Wiley (John Wiley & Sons) โš– 403 KB ๐Ÿ‘ 1 views

The increasing demands on the quality and consumption safety of grain imply, for food economy, increased expenditures for product and process supervision. Within the framework of the control of goods received and quality of the processing industries, various laboratory methods are applied at present

Acquisition-time image quality control i
โœ A. Gutenev; V.N. Skladnev; D. Varvel ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 193 KB

SolarScane is a prototype real time diagnostic instrument, which uses image analysis to detect malignancy of melanocytic skin lesions. It employs dermatoscopy as an imaging technique and is built around a 3-CCD analogue video camera. In order to obtain the image of maximum quality for the analysis t

Air Quality Control for Hazardous Bio-Ma
โœ Petra Perner ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› Wiley (John Wiley & Sons) โš– 642 KB

Airborne microorganisms are ubiquitously present in various indoor and outdoor environments. The potential implication of fungal contaminants in bio-aerosols on occupational health is recognized as a problem in several working environments. There is a concern on the exposure of workers to bio-aeroso

A quality control measure for longitudin
โœ Walter T. Ambrosius; Siu L. Hui ๐Ÿ“‚ Article ๐Ÿ“… 2000 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 236 KB ๐Ÿ‘ 2 views

At the time of data acquisition in a longitudinal study a decision needs to be made whether or not the latest measurement of the primary outcome is a potential outlier. If the data point does not "t with the subject's prior data, the patient can be immediately remeasured before he/she leaves the o$c

A fatigue test for controlling the quali
โœ Y. Zhou; X. Lu; Norman Brown ๐Ÿ“‚ Article ๐Ÿ“… 1991 ๐Ÿ› Society for Plastic Engineers ๐ŸŒ English โš– 513 KB

## Abstract The lifetimes of 17 commercial ethyleneโ€hexene copolymers were measured under fatigue and constant load. These LLDPE resins all had about the same melt flow index and density, but their lifetimes under fatigue and constant load varied by factors of 17 to 10^4^, respectively. The lifetim