An intramedullary implant model in the canine femora was developed to evaluate the mechanical and histological responses between cancellous bone and plasma-sprayed hydroxyapatite coatings (HACs) on Ti-6A1-4V implants, with 12-and 24-week follow-ups. HACs of different thicknesses were investigated. R
Tensile tests of interface between bone and plasma-sprayed HA coating-titanium implant
β Scribed by Lin, Hong ;Xu, Hengchang ;Zhang, Xingdong ;de Groot, Klaas
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 559 KB
- Volume
- 43
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Tensile strength testing of the interface between bone and a plasma-sprayed hydroxyapatite (HA) coating-Ti-6Al-4V (implant I) and an HA coating-Ti (implant II) was performed. The bone-implant interface and tensile failure mode were evaluated by light microscopy (LM), SEM-energy dispersive X-ray analysis, and backscattered electron imaging. The crystallinity of the HA coating of implant I and implant II was 62 and 40%, respectively. Eleven semidisk implants of each type were inserted in the left tibia of 22 rabbits in each period. After 2, 4, 8, and 16 weeks, the tensile strength of the boneimplant I was 0.86, 1.32, 1.10, and 0.92 MPa, respectively; the value of the bone-implant II was 0.66, 0.92, 0.84, and 1.12 MPa, respectively. No significant difference was found in tensile strength between implant I and implant II, and between the data of different periods. LM and SEM revealed that the two types of coatings behave the same in bone. Failure after the tensile test mainly occurred at the bony tissue at 2 and 4 weeks, inside the HA coating layer at 8 weeks, and at the HA coating-metal substrate interface at 16 weeks. Degradation and delamination of the HA coating continued with time, resulting in the interfacial tensile strength not increasing with time. Thus, we concluded that differences between the two implants, mainly the difference in crystallinity of the HA coating (62 vs. 40%), have no significant influence on bone bonding ability, bone bonding strength, tensile failure mode, and degradation of the coating.
π SIMILAR VOLUMES
The aim of this study was to investigate the biological and mechanical response of bone to titanium plasmasprayed implants of different roughnesses. Three types of titanium plasma-spray coating were applied to beamshaped implants: Ti2, Ti3, and Ti4, with a Ra of 16.5, 21.4, and 37.9 m, respectively.
Plasma-sprayed hydroxyapatite (HA) coatings on titanium alloy are often used in prosthetic implants. The metallic substrate gives the implant good mechanical strength which is combined with good biocompatibility and osteointegration of the ceramic coating. However, the interface between the HA coati
## Abstract The geometric design and chemical compositions of an implant surface may have an important part in affecting early implant stabilization and influencing tissue healing. In this study, __in vivo__ behavior and mechanical stability in implants of three surface designs, which were smooth s
The bone-bonding behavior of three kinds of bioactive ceramics coated on titanium alloy by the plasma-spray technique was investigated. Titanium alloy (Ti-6A1-4V) coated with BioglassR (45S5), apatite-wollastonite containing glass ceramic (AW), or p-tricalcium phosphate (TCP) was prepared, and recta
## Abstract Skeletal bone consists of hydroxyapatite (HA) [Ca~10~(PO~4~)~6~(OH)~2~] and collagen type I, both of which are osseoconductive. The goal of osseointegration of orthopedic and dental implants is the rapid achievement of a mechanically stable longβlasting fixation between bone and an impl