## Abstract A method is presented for measuring myocardial deformation in a breath‐hold with tagged cine MRI. Tagged cine images of human hearts are obtained in arbitrary oblique planes on a standard imager with as few as four heartbeats. The scan time has been reduced 16‐ to 64‐fold from previous
Tag contrast in breath-hold CINE cardiac MRI
✍ Scribed by Scott B. Reeder; Elliot R. McVeigh
- Publisher
- John Wiley and Sons
- Year
- 1994
- Tongue
- English
- Weight
- 448 KB
- Volume
- 31
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Contrast between tagged and nontagged myocardium was investigated using rapid gradient echo segmented k‐space CINE MRI. The transient behavior of magnetization was measured in stationary and moving phantoms using gradient recalled acquisition in steady‐state GRASS and spoiled GRASS (SPGR) sequences with TR ≈ 7 ms and TE ≈ 2.5 ms. Bloch equation simulations were used to compute theoretical results. Understanding the transient behavior of magnetization is important because tags only persist in the myocardium during the nonequilibrium transition to steady state. The transition to steady state for both SPGR and GRASS is reproducible after one heartbeat, and including unprocessed data from the first heartbeat leads to image artifacts. In a moving phantom, simulations and experimental results showed that GRASS and SPGR are essentially equivalent. Tag‐tissue contrast in SPGR was very sensitive to imaging tip angle. The optimum tip angle for the scanning parameters used in this study was 11°.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To correct for spatial misregistration of multi‐breath‐hold short‐axis (SA), two‐chamber (2CH), and four‐chamber (4CH) cine cardiac MR (CMR) images caused by respiratory and patient motion. ## Materials and Methods Twenty CMR studies from consecutive patients with separate
Cardiac MRI function measurements are typically performed using 2D sequences and require multiple breath-holds to image the entire heart. A single 3D acquisition using a T(1)-shortening agent has many potential advantages over techniques that acquire multiple 2D images, including more consistent con
## Abstract The purpose of this paper was to evaluate the use of dynamic gadopentetate dimeglumine‐enhanced, breath‐hold spoiled gradient‐recalled (SPGR) MR imaging with cardiac compensation (CMON) compared to spin‐echo MR imaging in patients with thoracic malignancy. We retrospectively reviewed MR
## Abstract ## Purpose To improve the tag persistence throughout the whole cardiac cycle by providing a constant tag‐contrast throughout all the cardiac phases when using balanced steady‐state free precession (bSSFP) imaging. ## Materials and Methods The flip angles of the imaging radiofrequency