𝔖 Bobbio Scriptorium
✦   LIBER   ✦

T1 relaxation in in vivo mouse brain at ultra-high field

✍ Scribed by Rob C.G. van de Ven; Bianca Hogers; Arn M.J.M. van den Maagdenberg; Huub J.M. de Groot; Michel D. Ferrari; Rune R. Frants; Robert E. Poelmann; Louise van der Weerd; Suzanne R. Kiihne


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
243 KB
Volume
58
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Accurate knowledge of relaxation times is imperative for adjustment of MRI parameters to obtain optimal signal‐to‐noise ratio (SNR) and contrast. As small animal MRI studies are extended to increasingly higher magnetic fields, these parameters must be assessed anew. The goal of this study was to obtain accurate spin‐lattice (T~1~) relaxation times for the normal mouse brain at field strengths of 9.4 and 17.6 T. T~1~ relaxation times were determined for cortex, corpus callosum, caudate putamen, hippocampus, periaqueductal gray, lateral ventricle, and cerebellum and varied from 1651 ± 28 to 2449 ± 150 ms at 9.4 T and 1824 ± 101 to 2772 ± 235 ms at 17.6 T. A field strength–dependent increase of T~1~ relaxation times is shown. The SNR increase at 17.6 T is in good agreement with the expected SNR increase for a sample‐dominated noise regime. Magn Reson Med 58:390–395, 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


In vivo ultra-high-field magnetic resona
✍ Roland Krug; Julio Carballido-Gamio; Suchandrima Banerjee; Andrew J. Burghardt; 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 419 KB 👁 1 views

## Abstract ## Purpose To investigate the feasibility of 7T magnetic resonance imaging (MRI) to visualize and quantify trabecular bone structure in vivo by comparison with 3T MRI and in vivo three‐dimensional (3D) high‐resolution peripheral quantitative computed tomography (HR‐pQCT). ## Materials

Gadodiamide T1 relaxivity in brain tissu
✍ Stephen Pickup; Andrew K. W. Wood; Harold L. Kundel 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 330 KB

## Abstract In vivo measurements of gadodiamide (Gd‐DTPA‐BMA) __T__~1~ relaxivity were performed at 4.7 T in injured and normal rat brains. Cerebral lesions were induced in nine rats by a localized freezing method. __T__~1~ maps of the lesions were generated before and after injection of Gd‐DTPA‐BM

In vivo detection of MRI-PARACEST agents
✍ Alex X. Li; Mojmir Suchy; Chunhui Li; Joseph S. Gati; Susan Meakin; Robert H. E. 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 316 KB

## Abstract Paramagnetic chemical exchange saturation transfer (PARACEST) contrast agents are under development for biological target identification by magnetic resonance imaging. Image contrast associated with PARACEST agents can be generated by radiofrequency irradiation of the chemically shifted

In vivo measurements of T1 relaxation ti
✍ Yu-Ting Kuo; Amy H. Herlihy; Po-Wah So; Kishore K. Bhakoo; Jimmy D. Bell 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 373 KB 👁 1 views

## Abstract ## Purpose To measure regional T1 and T2 values for normal C57Bl/6 mouse brain and changes in T1 after systemic administration of manganese chloride (MnCl~2~) at 9.4 T. ## Materials and Methods C57Bl/6 mice were anesthetized and baseline T1 and T2 measurements obtained prior to measu

Method to determine in vivo the relaxati
✍ Philippe Choquet; Jean-Noël Hyacinthe; Guillaume Duhamel; Emmanuelle Grillon; Je 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 130 KB 👁 1 views

## Abstract The magnetic polarization of the stable ^129^Xe isotope may be enhanced dramatically by means of optical techniques and, in principle, hyperpolarized ^129^Xe MRI should allow quantitative mapping of cerebral blood flow with better spatial resolution than scintigraphic techniques. A para