β¦ Synopsis
A sample introduction system for capillary supercritical fluid chromatography, which allows the dissolution of the sample in the supercritical mobile phase before being introduced into the column, was constructed and evaluated. Supercritical n-pentane was shown to solvate high-molecular-weight polycyclic aromatic compounds that could not be solvated using typical liquid solvents. In addition, split injection of a supercritical fluid solution was found to be more reproducible than split injections of a liquid solution. The potential of such an injection system was demonstrated, although further developments are needed in order to make the technique of practical utility.
π SIMILAR VOLUMES
An analysis of the precision obtained using commercially available microvalve injectors is reported for three modes of injection: conventional split; timed-split; and direct. Results from this study show that good precision (< 3% RSD for external standard and < 1% RSD for internal standard methods)
The principal applications of supercritical fluid chromatography (SFC) are for compounds that are thermally labile, of low volatility, of moderate polarity, or present in mixtures too complex for adequate separation using HPLC. Many compounds of biological and pharmaceutical interest are defined by
## Abstract The modifications made to a flame ionization detector (FID) to facilitate the detection of large molecular weight polar compounds analyzed by capillary supercritical fluid chromatography are described. Some specific examples are given to demonstrate that polar compounds can be effective
## Abstract The chromatographic characteristics of a liquid crystal bonded phase have been evaluated for the separation of polycyclic aromatic hydrocarbons (PAHs), especially focusing on its shape recognition capability in supercritical fluid chromatography (SFC). The results clearly indicate that
## Abstract A experimental design optimization method is demonstrated for evaluation of the resolution of the performance mixture used in the proposed ASTM test to determine the aromatic content of aviation fuels. The method uses a __Doehlert__ experimental matrix test to optimize the resolution an