๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Studies of variability in dissolution testing with USP apparatus 2

โœ Scribed by Gao, Zongming (author);Moore, Terry W. (author);Smith, Anjanette P. (author);Doub, William H. (author);Westenberger, Benjamin J. (author)


Publisher
John Wiley and Sons Inc.
Year
2007
Tongue
English
Weight
273 KB
Volume
96
Category
Article
ISSN
0022-3549

No coin nor oath required. For personal study only.

โœฆ Synopsis


In this study, gauge repeatability and reproducibility (gauge R&R) was used to analyze variability for USP apparatus 2 dissolution measurement systems. Experiments were designed to assess the variability due to apparatus, operator, and sample tablet. Since dissolution testing is a destructive test, a nested model was used for data analysis. Additionally, perturbation tests with both disintegrating and nondisintegrating tablets were performed to study the variability due to sample position within the dissolution vessel. For the gauge R&R study, two well-trained chemists used two mechanically calibrated USP apparatus 2 units. Six tests were performed by each operator on each apparatus. Evaluation of dissolution test results at 30 min using an internal DPA calibrator tablet NCDA#2 (10 mg prednisone) indicates that the main contribution to the total variance, approximately 70%, is due to the sample tablets, approximately 25% is from the apparatus and approximately 5% is due to the operators. There is no significant difference between operators and apparatuses as shown by the gauge R&R studies. In addition, dissolution results can be strongly affected by the position of the tablet within the vessel. Similarity (f 1 ) and dissimilarity (f 2 ) factors were calculated to statistically evaluate differences between perturbed and normal dissolution tests.


๐Ÿ“œ SIMILAR VOLUMES


Systematic error associated with apparat
โœ Don C. Cox; William B. Furman ๐Ÿ“‚ Article ๐Ÿ“… 1982 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 229 KB

The authors thank Robert E. Graham for providing the degradation products and commercial samples. Laura M. Tuck lor her analytical work on the enema, and Stephen M. Walters for a constructive editorial review.

Experimental and computational determina
โœ Ge Bai; Piero M. Armenante; Russell V. Plank ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 441 KB

Blend time, the time to achieve a predefined level of homogeneity of a tracer in a mixing vessel, is an important parameter to evaluate the mixing efficiency of mixing devices. In this work, the blend time required to homogenize the liquid content of a USP Dissolution Testing Apparatus II under a nu

MRI Studies of the Hydrodynamics in a US
โœ G. Shiko; L. F. Gladden; A. J. Sederman; P. C. Connolly; J. M. Butler ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 413 KB

We present a detailed study of hydrodynamics inside the flow-through dissolution apparatus when operated according to USP recommendations. The pulsatile flow inside the flow-through cell was measured quantitatively using magnetic resonance imaging (MRI) at a spatial resolution of 234 ร— 234 :m 2 and