𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Stereoselective analysis of tiopronin enantiomers in rat plasma using high-performance liquid chromatography-electrospray ionization mass spectrometry after chiral derivatization

✍ Scribed by Huan Wang; Chen Ma; Jia Zhou; Xiao Quan Liu


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
394 KB
Volume
21
Category
Article
ISSN
0899-0042

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A specific and relatively sensitive high‐performance liquid chromatography‐electrospray ionization mass spectrometry (HPLC‐ESI‐MS) was developed for the quantitative analysis of tiopronin enantiomers in rat plasma. The method is based on the derivatization of (+)‐tiopronin and (−)‐tiopronin with 2,3,4,6‐tetra‐O‐acetyl‐β‐glucopyranosyl isothiocyanate (GITC) in acetonitrile. The separation of resulting diastereomic derivatives was performed on C~18~ column (150 mm × 2.0 mm ID, packed with 5.0 μm C~18~ silica RP particle), using a mobile phase of methanol/water (containing 5.3 mM formic acid) with gradient elution. LC–MS was performed in the selected ion monitoring and positive ion mode using target ions at m/z: 575 for the diastereomic derivatives of tiopronin and m/z: 603 for the derivative of N‐isobutyryl‐D‐cysteine (internal standard). The method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability. The calibration curves were linear over the concentration range of 0.025–5 μg/ml for both enantiomers of tiopronin. For both enantiomers of tiopronin, the interbatch and intrabatch variability values were less than 15%, and the accuracy was within ±17% in terms of relative error. The method was successfully applied to a pharmacokinetic study of rac‐tiopronin in rat. Chirality, 2009. © 2008 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Quantitative determination of E5880 in r
✍ Kikuchi, Kiyomi; Sano, Yoshihisa; Taniguchi, Sachie; Matsui, Kenji; Namiki, Masa 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 130 KB 👁 2 views

A simple and sensitive method is described for the determination of E5880 in rat plasma. The method is based on high-performance liquid chromatography/electrospray ionization mass spectrometry, using deuterated E5880 as an internal standard. Selected reaction monitoring is employed for selectivity a

Quantification of fudosteine in human pl
✍ Fengguo Xu; Zunjian Zhang; Haoyan Jiao; Yuan Tian; Beibei Zhang; Yun Chen 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 148 KB

## Abstract This paper describes a novel method for the sensitive and selective determination of fudosteine in human plasma. The method involves a derivatization step with 9‐fluorenylmethyl chloroformate (FMOC‐Cl) in borate buffer and detection based on high‐performance liquid chromatography‐electr