Abstract

Steady‐state imaging techniques offer the potential to couple high spatial and temporal resolution with good signal‐to‐noise ratio (SNR), which makes them ideally suited for fluoroscopic applications. However, disturbance of the steady state can result in artifacts and substantially reduced signal levels. In this study the use of steady‐state imaging techniques was investigated as a means of guiding endovascular interventions with fluoroscopic MRI. Devices containing localized susceptibility defects were shown to disturb the steady‐state signal of spins that pass through the magnetic field disturbances. It was demonstrated that these effects are appreciable and can make delineation of interventional devices difficult in the presence of flow. T~1~‐shortening contrast agents were shown to dramatically reduce these effects by reducing the time taken to achieve steady state. The addition of a blood pool agent in an in vivo model was found to be necessary for adequate visualization of a dysprosium‐marked catheter. Magn Reson Med 50:434–438, 2003. © 2003 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Starter sequence for steady-state free p
✍ D. L. Foxall 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 916 KB

## Abstract The dynamic equilibrium exploited by balanced steady‐state free precession imaging develops slowly because its formation is dependent on both spin–spin and spin–lattice relaxation times. Attempting to image before steady state is established results in artifacts due to transient signal

Steady-state preparation for spoiled gra
✍ Reed F. Busse; Stephen J. Riederer 📂 Article 📅 2001 🏛 John Wiley and Sons 🌐 English ⚖ 376 KB

## Abstract While spoiled gradient echo sequences provide a rapid means of acquiring __T__~1~‐weighted images, it is often desirable that the magnetization be in the steady state to avoid artifacts. For some applications, this requires many “dummy” repetitions of the pulse sequence prior to data co

Outer volume suppression in steady state
✍ Jaane Rauschenberg; Axel J. Krafft; Florian Maier; Patrik Zamecnik; Wolfhard Sem 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 665 KB

## Abstract Magnetic resonance‐guided percutaneous interventions with needles require fast pulse sequences with acquisition times less than 1 s to image the needle trajectory within moving organs. To guide the movement of a rigid instrument with high sampling rate, an magnetic resonance imaging met