Exploration of the possibilities of steady-state free precession (SSFP) excitation has led to the discovery that it is tolerant of slow variations in spectral offset frequency. The effect has been used to eliminate banding artifacts from images obtained with the fully balanced SSFP imaging sequence.
Starter sequence for steady-state free precession imaging
✍ Scribed by D. L. Foxall
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 916 KB
- Volume
- 53
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The dynamic equilibrium exploited by balanced steady‐state free precession imaging develops slowly because its formation is dependent on both spin–spin and spin–lattice relaxation times. Attempting to image before steady state is established results in artifacts due to transient signal oscillations. Using a starter sequence to precondition the spin system can significantly reduce the delay before imaging. An improved design for a steady‐state starter sequence is presented. The new sequence has the advantage of uniformly exciting the steady‐state response for all resonance offsets and can be phase cycled to suppress banding artifacts. Magn Reson Med 53:919–929, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Steady‐state free precession (SSFP) pulse sequences employing gradient reversal echoes and short repetition time (TR) between successive rf excitation pulses offer high signal‐to‐noise ratio per unit time. However, SSFP sequences are very sensitive to motion. A new SSFP method is presen
## Abstract The formerly proposed concept for magnetization transfer imaging (MTI) using balanced steady‐state free precession (SSFP) image acquisitions is in this work extended to nonbalanced protocols. This allows SSFP‐based MTI of targets with high susceptibility variation (such as the musculosk
## Abstract The addition of a single, unbalanced diffusion gradient to the steady‐state free precession (SSFP) imaging sequence sensitizes the resulting signal to free diffusion. Unfortunately, the confounding influence of both longitudinal (__T__~__1__~) and transverse (__T__~__2__~) relaxation on
## Abstract Balanced steady‐state free precession (SSFP) sequences are useful in cardiac imaging because they achieve high signal efficiency and excellent blood–myocardium contrast. Spiral imaging enables the efficient acquisition of cardiac images with reduced flow and motion artifacts. Balanced S
Reversal of the read gradient in a SSFP imaging experiment allows a full spin echo to be collected in the interval T between successive rfpulses. Orthogonal gradient pulses are used to dephase and subsequently rephase the transverse magnetization each T enabling 2D or 3D Fourier techniques. The mini