Stability of the FID sensitivity during an analysis in capillary GC
โ Scribed by Grob, K.
- Publisher
- John Wiley and Sons
- Year
- 1980
- Tongue
- English
- Weight
- 401 KB
- Volume
- 3
- Category
- Article
- ISSN
- 0935-6304
No coin nor oath required. For personal study only.
โฆ Synopsis
Abstract
The sensitivity of an FID may change when the carrier gas flow rate changes during a chromatographic run. Sample parts which are eluted at reduced FID sensitivity produce a reduced peak area, hence are discriminated as compared to other components. Sensitivity changes were studied for hydrogen as carrier gas. For the detector tested, differences in the carrier gas flow rates of 1 ml/min shifted the FID sensitivity by 1 to 5% (depending on the fuel gas supply). Thus the stability of the sensitivity is no longer ensured as soon as the carrier gas flow rate is changed manually or by an automatic programmer during an analysis. Sensitivity drifts may also occur during temperature programmed runs with a pressure regulated carrier gas supply since the gas flow through the capillary drops with increasing temperature. Such shifts in the response became noticeable as soon as relatively high carrier gas flow rates combined with long range temperature programmes were used. The typical patterns of such discriminations are shown, closing with a discussion on the possibilities for minimizing such undesired effects.
๐ SIMILAR VOLUMES
The analysis of complex mixtures, such as essential oils requires high resolution chromatographic separation and even the use of very efficient columns cannot prevent the overlapping of certain peaks. This means that it is very difficult to obtain high quality mass spectra when the sample contains n
## Abstract Three methods were evaluated for the determination of O^6^โmonoacetylmorphine (6โMAM), the specific metabolite of heroin in human urine, by GCโNPDโFID. The procedure devised for a hydrophobic cation exchange column showed superior performances over the liquidโliquid extraction technique
## Abstract Recent works have attracted interest toward sensitivity measures that use the entire model output distribution, without dependence on any of its particular moments (e.g., variance). However, the computation of momentโindependent importance measures in the presence of dependencies among